欢迎访问ic37.com |
会员登录 免费注册
发布采购

GRM1555C1H3R0WA01D 参数 Datasheet PDF下载

GRM1555C1H3R0WA01D图片预览
型号: GRM1555C1H3R0WA01D
PDF下载: 下载PDF文件 查看货源
内容描述: 片状独石陶瓷电容器 [Chip Monolithic Ceramic Capacitors]
分类和应用: 电容器陶瓷电容器
文件页数/大小: 221 页 / 4341 K
品牌: MURATA [ muRata ]
 浏览型号GRM1555C1H3R0WA01D的Datasheet PDF文件第206页浏览型号GRM1555C1H3R0WA01D的Datasheet PDF文件第207页浏览型号GRM1555C1H3R0WA01D的Datasheet PDF文件第208页浏览型号GRM1555C1H3R0WA01D的Datasheet PDF文件第209页浏览型号GRM1555C1H3R0WA01D的Datasheet PDF文件第211页浏览型号GRM1555C1H3R0WA01D的Datasheet PDF文件第212页浏览型号GRM1555C1H3R0WA01D的Datasheet PDF文件第213页浏览型号GRM1555C1H3R0WA01D的Datasheet PDF文件第214页  
• This PDF catalog is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our  
!Note  
C02E.pdf  
10.12.20  
sales representatives or product engineers before ordering.  
• This PDF catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.  
!Caution  
Continued from the preceding page.  
3. Fail-safe  
Failure of a capacitor may result in a short circuit. Be sure  
to provide an appropriate fail-safe function such as a fuse  
on your product to help eliminate possible electric shock,  
fire, or fumes.  
FUSE  
AC IN  
Please consider using fuses on each AC line if the  
capacitors are used between the AC input lines and earth  
(line bypass capacitors), to prepare for the worst case,  
such as a short circuit.  
4. Test Condition for AC Withstanding Voltage  
(1) Test Equipment  
Tests for AC withstanding voltage should be made with  
equipment capable of creating a wave similar to a  
50/60 Hz sine wave.  
If the distorted sine wave or overload exceeding the  
specified voltage value is applied, a defect may be  
caused.  
(2) Voltage Applied Method  
The capacitor's leads or terminals should be firmly  
connected to the output of the withstanding voltage test  
equipment, and then the voltage should be raised from  
near zero to the test voltage. If the test voltage is applied  
directly to the capacitor without raising it from near zero,  
it should be applied with the zero cross.* At the end of the  
test time, the test voltage should be reduced to near zero,  
and then the capacitor's leads or terminals should be  
taken off the output of the withstanding voltage test  
equipment. If the test voltage is applied directly to the  
capacitor without raising it from near zero, surge voltage  
may occur and cause a defect.  
Voltage sine wave  
*ZERO CROSS is the point where voltage sine wave  
passes 0V.  
0V  
- See the figure at right -  
zero cross  
FAILURE TO FOLLOW THE ABOVE CAUTIONS MAY  
RESULT, WORST CASE, IN A SHORT CIRCUIT AND  
CAUSE FUMING OR PARTIAL DISPERSION WHEN THE  
PRODUCT IS USED.  