• This PDF catalog is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our
• Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
!Note
!Note
C02E.pdf
10.12.20
sales representatives or product engineers before ordering.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
• This PDF catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
AC250V(r.m.s.) Type (Which Meet Japanese Law) Specifications and Test Methods
GA2 Series Specifications and Test Methods
Continued from the preceding page.
No.
Item
Specifications
Test Method
Appearance
No marking defects
Let the capacitor sit at 40T2D and relative humidity of 90 to 95%
W24
Capacitance
Change
Within T15%
for 500Y 0hrs.
Humidity
Remove and let sit for 24T2 hrs. at room condition,* then
17 (Steady
State)
D.F.
I.R.
0.05 max.
measure.
#Pretreatment
More than 1,000MΩ
W 0
ꢀ
Perform a heat treatment at 150Y10D for 60T5 min. and then
let sit for 24T2 hrs. at room condition.*
Dielectric
Strength
In accordance with item No.4
No marking defects
Within T20%
Appearance
Apply voltage and time as in Table at maximum operating
temperature T3D. Remove and let sit for 24T2 hrs. at room
condition,* then measure. The charge / discharge current is
less than 50mA.
Capacitance
Change
D.F.
I.R.
0.05 max.
Nominal Capacitance
CU10,000pF
Test Time
W48
Test Voltage
More than 1,000MΩ
ꢀ
*
ꢀ
1,500Y 0 hrs. AC500V (r.m.s.)
18 Life
CF10,000pF
* Except that once each hour the voltage is increased to
AC1,000V (r.m.s.) for 0.1 sec.
Dielectric
Strength
In accordance with item No.4
#Pretreatment
Apply test voltage for 60T5 min. at test temperature.
Remove and let sit for 24T2 hrs. at room condition.*
Appearance
No marking defects
Apply the rated voltage at 40T2D and relative humidity of 90 to
W24
Capacitance
Change
Within T15%
95% for 500Y 0hrs.
Remove and let sit for 24T2 hrs. at room condition,* then
measure.
#Pretreatment
Apply test voltage for 60T5 min. at test temperature.
Remove and let sit for 24T2 hrs. at room condition.*
Humidity
19
D.F.
I.R.
0.05 max.
Loading
More than 1,000MΩ
Dielectric
Strength
In accordance with item No.4
* "Room condition" Temperature: 15 to 35D, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa
190