• This PDF catalog is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our
• Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
!Note
!Note
C02E.pdf
10.12.20
sales representatives or product engineers before ordering.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
• This PDF catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
Only for Camera Flash Circuit Specificati n and Test Methods
GR7 Series Specifications and Test Methods
Continued from the preceding page.
No.
Item
Specifications
Test Method
Appearance
No marking defects
Within T15%
0.05 max.
W48
Apply DC350V for 1,000Y 0 hrs. at maximum operating
temperature T3D. Remove and let sit for 24T2 hrs. at room
condition,* then measure.
Capacitance
Change
D.F.
I.R.
16 Life
The charge/discharge current is less than 50mA.
#Pretreatment
CU0.01µF: More than 10MΩ • µF
CF0.01µF: More than 1,000MΩ
Apply test voltage for 60T5 min. at test temperature.
Remove and let sit for 24T2 hrs. at room condition.*
Dielectric
Strength
In accordance with item No.4
No marking defects
Within T15%
Appearance
Capacitance
Change
Apply the rated voltage at 40T2D and relative humidity of 90 to
W24
95% for 500Y 0 hrs.
Remove and let sit for 24T2 hrs. at room condition,* then
measure.
#Pretreatment
Apply test voltage for 60T5 min. at test temperature.
Remove and let sit for 24T2 hrs. at room condition.*
Humidity D.F.
Loading
0.05 max.
17
CU0.01µF: More than 10MΩ • µF
CF0.01µF: More than 1,000MΩ
I.R.
Dielectric
Strength
In accordance with item No.4
* "Room condition" Temperature: 15 to 35D, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa
186