■AEC-Q200 Murata Standard Specification and Test Methods
No
AEC-Q200 Test Item
Specification.
AEC-Q200 Test Method
21 Capacitance
Temperature
Capacitance
Change
R7 : Within ±15%
The capacitance change should be measured after 5min. at
each specified temperature stage.
(-55℃ to +125℃)
Characteristics
The ranges of capacitance change compared with the above 25℃
value over the temperature ranges shown in the table should be
within the specified ranges.
Step
Temperature(℃)
25±2
1
2
3
4
5
-55±3(for R7)
25±2
125±3(for R7)
25±2
Initial measurement for high dielectric constant type.
Perform a heat treatment at 150+0/-10℃ for 1h
and then set for 24±2h at room temperature.
Perform the initial measurement.
JEMCGS-00806C