Freescale Semiconductor, Inc.  
Media Compatibility Disclaimer  
Motorola has tested media tolerant sensor devices in  
selected solutions or environments and test results are  
based on particular conditions and procedures selected by  
Motorola. Customers are advised that the results may vary  
for actual services conditions. Customers are cautioned that  
they are responsible to determine the media compatibility of  
sensor devices in their applications and the foreseeable use  
and misuses of their applications.  
Sensor Media Compatibility: Issues and Answers  
T. Maudie, D. J. Monk, D. Zehrbach, and D. Stanerson  
Motorola Semiconductor Products Sector, Sensor Products Division  
5005 E. McDowell Rd., Phoenix, AZ 85018  
The applicability of media compatibility affects all sensors to  
ABSTRACT  
some degree, but perhaps none more dramatically than a  
piezoresistive pressure sensor. In order to provide an  
accurate, linear output with applied pressure, the media  
should come in direct contact with the silicon die. Any barrier  
provided between the die and the media, limits the device  
performance. A typical piezoresistive diaphragm pressure  
sensor manufactured using bulk micromachining techniques  
is shown in Figure 1. A definition for a media compatible  
pressure sensor will be proposed.  
To ensure accurate media testing, the requirements and  
methods need to be understood, as well as what constitutes  
a failure. An understanding of the physics of failure can  
significantly reduce the development cycle time and produce  
As sensors and actuators are embedded deeper into  
electronic systems, the issue of media compatibility as well as  
sensor and actuator performance and survivability becomes  
increasingly critical. With a large number of definitions and  
even more explanations of what media compatibility is, there  
is a ground swell of confusion not only within the industry, but  
among end users as well. The sensor industry must respond  
to create a clear definition of what media compatibility is, then  
strive to provide a comprehensive understanding and industry  
wide agreement on what is involved in assessing media  
tolerance and compatibility. Finally, the industry must create  
a standard set of engineering parameters to design, evaluate,  
test, and ultimately qualify sensor and actuators functioning in  
various media conditions. This paper defines media  
compatibility, identifies pertinent compatibility issues, and  
recommends a path to industry standardization.  
a
higher quality product [5,6]. The focus of the  
physics–of–failure approach includes the failure mechanism,  
accelerating environment, and failure mode. The requirement  
for a typical pressure sensor application involves long term  
exposure to a variety of media at an elevated temperature and  
may include additional acceleration components such as  
static or cyclic temperature and pressure.  
INTRODUCTION  
Microelectromechanical System (MEMS) reliability in  
various media is a subject that has not yet received much  
attention in the literature yet [1–3], but does bring up many  
potential issues. The effects of long term media exposure to  
the silicon MEMS device and material still need answers [4].  
Testing can result in predictable silicon or package related  
failures, but due to the complexity of the mechanisms,  
deleterious failures can be observed. The sensor may be  
exposed to diverse media in markets such as automotive,  
industrial, and medical. This media may include polar or  
nonpolar organic liquids, acids, bases, or aqueous solutions.  
Integrated circuits (ICs) have long been exposed to  
temperature extremes, humid environments, and mechanical  
tests to demonstrate or predict the reliability of the device for  
the application. Unlike a typical IC, a sensor often must exist  
in direct contact with a harsh environment. The lack of harsh  
media simulation test standardization for these direct contact  
situations necessitates development of methods and  
hardware to perform reliability tests.  
DIFFUSED  
DIAPHRAGM STRAIN GAUGE METALLIZATION  
SILICON  
WAFER  
ETCHED  
CAVITY  
DIE  
WIRE  
INTERCONNECT  
RTV DIE BOND  
LEAD  
FRAME  
EPOXY  
CASE  
This paper was presented at Sensors Expo, Anaheim, CA, and is  
reprinted with permission, Sensors Magazine (174 Concord St.,  
Peterborough, NH 03458) and Expocon Management Associates,  
Inc. (P.O. Box 915, Fairfield, CT 06430).  
Figure 1. Typical bulk micromachined silicon  