Retry Termination  
HALT and BERR are asserted in lieu of, at the same time as, or before DSACK  
(case 5) or after DSACK (case 6); BERR is negated at the same time or after  
DSACK; HALT may be negated at the same time or after BERR.  
Table 4-14 shows various combinations of control signal sequences and the resulting  
bus cycle terminations.  
Table 4-14 DSACK, BERR, and HALT Assertion Results  
Case  
Number  
Control  
Signal  
Asserted on  
Rising Edge  
of State  
Result  
N
N + 2  
1
2
3
4
5
6
DSACK  
BERR  
HALT  
A
NA  
NA  
S
NA  
X
Normal termination.  
DSACK-  
BERR  
HALT  
A
NA  
A/S  
S
NA  
S
Halt termination: normal cycle terminate and halt.  
Continue when HALT is negated.  
DSACK-  
BERR  
HALT  
NA/A  
A
NA  
X
S
X
Bus error termination: terminate and take bus error  
exception, possibly deferred.  
4
DSACK-  
BERR  
HALT  
A
A
NA  
X
S
NA  
Bus error termination: terminate and take bus error  
exception, possibly deferred.  
DSACK-  
BERR  
HALT  
NA/A  
A
A/S  
X
S
S
Retry termination: terminate and retry when HALT is  
negated.  
DSACK-  
BERR  
HALT  
A
NA  
NA  
X
A
A
Retry termination: terminate and retry when HALT is  
negated.  
NOTES:  
N
A
= The number of current even bus state (S2, S4, etc.).  
= Signal is asserted in this bus state.  
NA = Signal is not asserted in this state.  
X
S
= Don't care.  
= Signal was asserted in previous state and remains asserted in this state.  
To properly control termination of a bus cycle for a retry or a bus error condition,  
DSACK, BERR, and HALT must be asserted and negated with the rising edge of the  
MCU clock. This ensures that when two signals are asserted simultaneously, the re-  
quired setup time and hold time for both of them are met for the same falling edge of  
the MCU clock. (Refer to APPENDIX A ELECTRICAL CHARACTERISTICS for timing  
requirements.) External circuitry that provides these signals must be designed with  
these constraints in mind, or else the internal bus monitor must be used.  
DSACK, BERR, and HALT may be negated after AS is negated.  
WARNING  
If DSACK or BERR remain asserted into S2 of the next bus cycle,  
that cycle may be terminated prematurely.  
MC68331  
SYSTEM INTEGRATION MODULE  
MOTOROLA  
4-31  
USER’S MANUAL  
 