 浏览型号V54C3256164VALT6的Datasheet PDF文件第13页浏览型号V54C3256164VALT6的Datasheet PDF文件第14页浏览型号V54C3256164VALT6的Datasheet PDF文件第15页浏览型号V54C3256164VALT6的Datasheet PDF文件第16页浏览型号V54C3256164VALT6的Datasheet PDF文件第18页浏览型号V54C3256164VALT6的Datasheet PDF文件第19页浏览型号V54C3256164VALT6的Datasheet PDF文件第20页浏览型号V54C3256164VALT6的Datasheet PDF文件第21页  
V54C3256(16/80/40)4V(T/S/B)  
Operating Currents (T = 0 to 70°C, V = 3.3V ± 0.3V)  
A
CC  
(Recommended Operating Conditions unless otherwise noted)  
Max.  
Symbol Parameter & Test Condition  
-6  
-7 / -7PC -8PC  
Unit  
Note  
ICC1  
Operating Current  
RC = tRCMIN., tRC = tCKMIN  
1 bank operation  
250  
230  
210  
mA  
7
t
.
Active-precharge command cycling,  
without Burst Operation  
ICC2P  
Precharge Standby Current  
in Power Down Mode  
tCK = min.  
CK = Infinity  
2
1
2
1
2
1
mA  
mA  
7
7
ICC2PS  
t
CS =VIH, CKEVIL(max)  
ICC2N  
Precharge Standby Current  
in Non-Power Down Mode  
CS =VIH, CKEVIL(max)  
tCK = min.  
tCK = Infinity  
55  
5
45  
5
35  
5
mA  
mA  
ICC2NS  
ICC3N  
ICC3P  
ICC4  
No Operating Current  
CKE VIH(MIN.)  
65  
10  
55  
10  
45  
10  
mA  
mA  
mA  
t
CK = min, CS = VIH(min)  
bank ; active state ( 4 banks)  
CKE VIL(MAX.)  
(Power down mode)  
Burst Operating Current  
tCK = min  
170  
150  
120  
7,8  
7
Read/Write command cycling  
ICC5  
ICC6  
Auto Refresh Current  
270  
240  
220  
mA  
t
CK = min  
Auto Refresh command cycling  
Self Refresh Current  
Self Refresh Mode, CKE0.2V  
3
3
3
mA  
mA  
L-version  
1.7  
1.7  
1.7  
(A component rev)  
L-version  
1.0  
1.0  
1.0  
mA  
(B component rev)  
Notes:  
7. These parameters depend on the cycle rate and these values are measured by the cycle rate under the minimum value of tCK and  
RC. Input signals are changed one time during tCK  
t
.
8. These parameter depend on output loading. Specified values are obtained with output open.  
V54C3256(16/80/40)4V(T/S/B) Rev. 1.6 September 2002  