MOSEL VITELIC
V54C365164VC
Operating Currents (T = 0 to 70°C, V = 3.3V 0.3V)
A
CC
(Recommended Operating Conditions unless otherwise noted)
Max.
-7
Symbol
Parameter & Test Condition
-6
-8PC
Unit Note
ICC1
Operating Current
1 bank operation
165
150
130
mA
7
t
= t
, t = t
.
CKMIN
RC
RCMIN. RC
Active-precharge command
cycling,
without Burst Operation
ICC2P
Precharge Standby Current
in Power Down Mode
CS =V , CKE≤ V
t
= min.
2
2
2
mA
7
7
CK
IH
IL(max)
ICC2PS
ICC2N
t
t
= Infinity
= min.
1
1
1
mA
mA
CK
CK
Precharge Standby Current
in Non-Power Down Mode
CS =V , CKE≥ V
55
45
35
IH
IL(max)
ICC2NS
ICC3
t
= Infinity
5
65
8
5
55
8
5
45
8
mA
mA
mA
mA
CK
No Operating Current
= min, CS = V
CKE ≥ V
CKE ≥ V
IH(MIN.)
t
CK
IH(min)
bank ; active state ( 4 banks)
ICC3P
ICC4
IL(MAX.)
(Power down mode)
Burst Operating Current
130
120
110
7,8
7
t
= min
CK
Read/Write command cycling
ICC5
ICC6
Auto Refresh Current
165
150
130
mA
t
= min
CK
Auto Refresh command cycling
Self Refresh Current
Self Refresh Mode, CKE=0.2V
1
1
1
mA
µA
L-version
400
400
400
Notes:
7. These parameters depend on the cycle rate and these values are measured by the cycle rate under the minimum value of t and
CK
t
. Input signals are changed one time during t
.
RC
CK
8. These parameter depend on output loading. Specified values are obtained with output open.
V54C365164VC Rev. 0.8 July 2001
11