MOSEL VITELIC
V54C365164VC
Absolute Maximum Ratings*
Operating temperature range ..................0 to 70 °C
Storage temperature range ............... -55 to 150 °C
Input/output voltage..................-0.3 to (V +0.3) V
CC
Power supply voltage ..........................-0.3 to 4.6 V
Power dissipation ............................................. 1 W
Data out current (short circuit)...................... 50 mA
*Note: Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage of the device.
Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
Recommended Operation and Characteristics for LV-TTL
T = 0 to 70 °C; V = 0 V; V ,V
= 3.3 V 0.3 V
A
SS
CC CCQ
Limit Values
min. max.
Parameter
Symbol
Unit Notes
Input high voltage
Input low voltage
V
2.0
– 0.3
2.4
–
Vcc+0.3
V
V
1, 2
1, 2
IH
V
0.8
–
IL
Output high voltage (I
= – 2.0 mA)
V
V
OUT
OH
Output low voltage (I
= 2.0 mA)
V
I
0.4
5
V
OUT
OL
Input leakage current, any input
– 5
µA
I(L)
(0 V < V < 3.6 V, all other inputs = 0 V)
IN
Output leakage current
I
– 5
5
µA
O(L)
(DQ is disabled, 0 V < V
< V
)
OUT
CC
Note:
1. All voltages are referenced to V
.
SS
2.
V
may overshoot to V + 2.0 V for pulse width of < 4ns with 3.3V. V may undershoot to -2.0 V for pulse width < 4.0 ns with
IH CC IL
3.3V. Pulse width measured at 50% points with amplitude measured peak to DC reference.
V54C365164VC Rev. 0.8 July 2001
10