V437316S04V
Operating Currents
T = 0°C to 70°C, V = 3.3V ± 0.3V (Recommended operating conditions otherwise noted) (Continued)
A
CC
Max.
-75PC/-
Symbol Parameter & Test Condition
75
-10PC
Unit
Note
ICC2P
Precharge Standby Current in Power Down Mode
CS =VIH, CKE≤ VIL(max)
tCK = min.
14
14
mA
7
ICC2PS
ICC2N
t
CK = Infinity
9
9
mA
mA
7
Precharge Standby Current in Non-Power Down Mode tCK = min.
400
315
CS =VIH, CKE≥ VIL(max)
ICC2NS
ICC3
tCK = Infinity
45
45
mA
mA
No Operating Current
CK = min, CS = VIH(min)
CKE ≥ VIH(MIN.)
495
405
t
bank ; active state ( 4 banks)
ICC3P
ICC4
CKE ≥ VIL(MAX.)
(Power down mode)
90
90
mA
mA
Burst Operating Current
tCK = min
990
810
7,8
7
Read/Write command cycling
ICC5
Auto Refresh Current
2250
1890
mA
tCK = min
Auto Refresh command cycling
ICC6
Self Refresh Current
Self Refresh Mode, CKE=0.2V
14
14
mA
mA
L-version
7.2
7.2
Notes:
1. These parameters depend on the cycle rate and these values are measured by the cycle rate under the minimum value of tCK and
RC. Input signals are changed one time during tCK
t
.
2. These parameter depend on output loading. Specified values are obtained with output open.
AC Characteristics
T = 0° to 70°C; V = 0V; V = 3.3V ± 0.3V, t = 1 ns
A
SS
CC
T
Limit Values
-75
-10PC
-75PC
#
Symbol Parameter
Min.
Max.
Min.
Max.
Min.
Max.
Unit
Note
Clock and Clock Enable
1
2
3
4
tCK
tCK
tAC
tCH
Clock Cycle Time
CAS Latency = 3
CAS Latency = 2
s
7.5
7.5
–
–
7.5
10
–
–
10
10
–
–
ns
ns
Clock Frequency
CAS Latency = 3
CAS Latency = 2
–
–
133
133
–
–
133
100
–
–
100
100
MHz
MHz
Access Time from Clock
CAS Latency = 3
2, 4
–
5.4
6
–
5.4
6
–
6
6
ns
ns
CAS Latency = 2
_
_
_
Clock High Pulse Width
2.5
–
2.5
–
2.5
–
ns
V437316S04V Rev. 1.0 December 2001
7