MT9075B  
Preliminary Information  
Bit  
Name  
Functional Description  
Bit  
Name  
Functional Description  
7
ASEL  
(0)  
AIS Select. This bit selects the  
criteria on which the detection of a  
valid Alarm Indication Signal (AIS)  
is based. If zero, the criteria is less  
than three zeros in a two frame  
period (512 bits). If one, the criteria  
is less than three zeros in each of  
7
TIU0  
(0)  
Transmit International Use Zero.  
When CRC-4 operation is disabled  
(CSYN=1), this bit is transmit on  
the PCM 30 2048 kbit/sec. link in  
bit position one of time-slot zero of  
frame-alignment frames. It is  
reserved for international use and  
should normally be kept at one. If  
CRC processing is used, i.e.,  
CSYN =0, this bit is ignored.  
two  
consecutive  
double-frame  
periods (512 bits per double-frame).  
6
MFSEL Multiframe  
determines  
Select.  
This  
bit  
which  
receive  
6
CRCM CRC-4 Modification. If one,  
(0)  
multiframe signal (CRC-4 or  
signalling) the RxMF (pin 42 in  
PLCC, 23 in MQFP) signal is  
aligned with. If zero, RxMF is  
aligned with the receive signalling  
multiframe. If one, RxMF is aligned  
with the receive CRC-4 multiframe.  
activates the CRC-4 remainder  
modification function when the  
device is in transparent mode. The  
received CRC-4 remainder is  
modified to reflect only the changes  
in the transmit DL. If zero, time slot  
zero data from DSTi will not be  
modified in transparent mode.  
(0)  
5
NBTB National Bit Transmit Buffer. If  
one, the transmit NFAS signal  
originates from the transmit national  
bit buffer; if zero, the transmit NFAS  
signal originates from the TNU4-8  
bits of page 01H, address 12H.  
5
4
RST  
(0)  
Reset. When this bit is changed  
from zero to one the device will  
reset to its default mode. See the  
Reset Operation section for the  
default settings.  
(0)  
4 - 0 S - S  
A one selects the corresponding S  
a
ARAI  
(0)  
Automatic RAI Operation. If  
zero, the Remote Alarm Indication  
a4  
a8  
bits of the NFA signal for 4, 8, 12,  
16 or 20 kbits/sec. data link  
channel. Data link (DL) selection will  
function in termination mode only; in  
(00000)  
bit (the  
A
bit) will function  
automatically. That is, RAI=0  
when basic synchronization has  
been acquired and RAI=1 when  
basic synchronization has not  
been acquired. If one, the remote  
alarm indication bit is controlled  
through the TALM bit of the  
transmit Non-Frame Alignment  
Control Word.  
transmit transparent mode S  
is  
a4  
automatically selected  
TxTRSP control bit of page 01H,  
address 11H. If zero, the  
corresponding bits of transmit non-  
frame alignment signal are  
-
see  
programmed by the Non-Frame  
Alignment Control Word (page  
01H, address 12H).  
3
AUTY Automatic Y-Bit Operation. If  
zero, the Y-bit of the transmit  
multiframe alignment signal will  
report the multiframe alignment  
status to the far end i.e., zero -  
multiframe alignment acquired, one  
- lost. If one, the Y-bit is under the  
manual control of the Transmit  
(0)  
Table 13 - Multiframe National Bit Buffer and DL  
Selection Word (Page 01H, Address 10H)  
Multiframe  
Word.  
Alignment  
Control  
Table 14 - Mode Selection Control Word  
(Page 01H, Address 11H)  
30  