MT9075B  
Preliminary Information  
single error events, which is a maximum rate of twice  
per CRC-4 multiframe.  
If the control bit ADSEQ is zero any combination of  
receive channels may be connected to the PRBS  
decoder (2 -1). Each error in the incoming  
15  
sequence causes the PRBS error counter to  
increment. The receive channels are selected by  
setting bit 2 (RRST) in the Per Time Slot Control  
Word.  
There is a maskable interrupts associated with the  
CRC error measurement. CRCI (page 01H, address  
1CH) is initiated when the least significant bit of the  
counter toggles, and CRCO (page 01H, address  
1DH) is initiated when the counter overflows.  
If the PRBS testing is performed in a metallic or  
external looparound the Per Time Slot Control Words  
with TTST (transmit test, bit 3) set should have  
RRST (receive test, bit 2) set at the same time.  
Error Insertion  
Six types of error conditions can be inserted into the  
transmit PCM 30 data stream through control bits,  
which are located on page 02H, address 10H. These  
error events include the bipolar violation errors  
(BPVE), CRC-4 errors (CRCE), FAS errors (FASE),  
NFAS errors (NFSE), payload (PERR) and a loss of  
signal error (LOSE). The LOSE function overrides  
the HDB3 encoding function.  
A-law Milliwatt  
If the control bit ADSEQ is one (from master control  
page 02H - access control word), the A-law digital  
milliwatt sequence (Table 10), defined by G.711, is  
available to be transmit on any combination of  
selected channels. The channels are selected by  
setting bit 3 (TTST), in the Per Time Slot Control  
Word.  
Per Time Slot Control  
There are two per time slot control pages (page 07H  
and 08H) occupying a total of 32 unique addresses.  
Each address controls a matching timeslot on the 32  
transmit channels (onto the line) and the equivalent  
channel data on the receive (DSTo) data. For  
example, address 0 of the first per time slot control  
page contains program control for transmit timeslot 0  
and DSTo channel 0.  
The same sequence is available to replace received  
data on any combination of DSTo channels. This is  
accomplished by setting bit 2 (RRST) in the Per Time  
Slot Control Word for the corresponding channel.  
Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8  
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
0
0
1
1
0
0
1
0
0
0
0
0
0
0
0
1
0
0
1
1
0
0
1
0
0
0
0
0
0
0
0
0
1
1
0
0
1
1
0
Per Time Slot Looping  
Any channel or combination of channels may be  
looped from transmit (sourced from DSTi) to receive  
(output on DSTo) STBUS channels. When bit 4  
(LTSL) in the Per Time Slot Control Word is set the  
data from the equivalent transmit timeslot is looped  
back onto the equivalent receive channel.  
Any channel or combination of channels may be  
looped from receive (sourced from the line data) to  
transmit (output onto the line) channels. When bit 5  
(RTSL) in the Per Time Slot Control Word is set the  
data from the equivalent receive timeslot is looped  
back onto the equivalent transmit channel.  
Table 10 - A-Law Digital Milliwatt Pattern  
Message Mode  
The transmit data on any of the transmit channels  
may be sourced either from the equivalent DSTi  
channel or from a dual port RAM programmed by the  
microport. The address of each dual port RAM  
memory location is uniquely associated with a  
transmit channel number. When bit 7 (TXMSG) in the  
Per Time Slot Control Word for that channel is set  
the transmit data for the channel is sourced from  
within the transmit message page dual port RAM (on  
page 0FH and 10H).  
PRBS Testing  
If the control bit ADSEQ is zero (from master control  
page 02H address 13H - Access Control Word), any  
channel or combination of transmit channels may be  
programmed to contain a generated pseudo random  
15  
bit sequence (2 -1). The channels are selected by  
setting bit 3 (TTST) in the Per Time Slot Control  
Word.  
26  