MT90220  
Address (Hex):  
Direct access  
Reset Value (Hex):  
0C0 - 0C3  
1 register per TX IMA Group  
58  
Bit #  
Type  
Description  
7
R/W  
R/W  
Reserved, write 0 for normal operation.  
6-5  
Value of M. These 2 bits specifies the value of M for the IMA Group.  
00: M=32,  
01: M=64,  
10: M=128  
11: M=256  
4
3
R/W  
R/W  
Timing Mode inserted in ICP cell. A 0 means that the ITC timing mode is inserted in the  
ICP cell and a 1 means that the CTC timing mode is inserted in the ICP cell.  
Timing Mode in RoundRobin scheduler. A 0 means that the ITC timing mode (adaptive)  
algorithm is selected and a 1 means that the CTC timing mode (fixed) algorithm is  
selected for internal operation.  
2:0  
R/W  
Reference Link. These 3 bits define which physical link is to be used as reference for  
timing purposes.  
Table 31 - TX Group Control Mode Registers  
Address (Hex):  
Direct access  
Reset Value (Hex):  
0DD- 0E4  
1 register per link, used in IMA mode only.  
0DD: 00, 0DE: 01 0DF: 02, 0E0: 03, 0E1: 04, 0E2: 05, 0E3: 06, 0E4: 07  
Bit #  
Type  
Description  
7:5  
4:0  
R/W  
R/W  
Reserved, must write 0 for normal operation.  
Link ID for the link N. The value can be between 0 and 31. This is the logical value  
associated to a physical link. Used in IMA mode only.  
Table 32 - TX Link ID Registers  
Address (Hex):  
Direct access  
Reset Value (Hex):  
0C4 - 0CB  
1 register per link, used in IMA mode only  
0C4: 00, 0C5: 01 0C6: 02, 0C7: 03, 0C8: 04, 0C9: 05, 0CA: 06, 0CB: 07  
Bit #  
Type  
Description  
7:0  
R/W  
Defines the ICP cell offset of link N. The value of M determines which significant bits are  
used as follows:  
M=256; bits 7-0 are used,  
M=128; bits 6-0 are used;  
M=64; bits 5-0 are used;  
M=32; bits 4-0 are used.  
Table 33 - TX ICP Cell Offset Registers  