ADVANCE INFORMATION  
VCT 38xxA  
The CPU telegram can be stopped after the 2 memory  
address bytes. The following I2C telegram subaddress-  
ing the data register will continue data transfer to or  
from the CPU memory. The data transfer will always  
start at the CPU memory address (autoincrement is  
not saved).  
3.14.1.3. Command Subaddressing  
TPU supports a command language, allowing the host  
controller to start complex processing inside the TPU  
with simple commands (see Section 3.12. on  
page 68). Commands have to be sent to the command  
subaddress.  
< 22 78 ah al dd .. >  
< 22 79 ah al dd .. >  
< 22 79 ah al > < 22 7C dd .. >  
The command subaddress has to be followed by the  
command code. The following data bytes are taken as  
command parameters.  
Data is directly written into CPU memory without using  
the I2C buffer of TPU and without waiting for a stop  
condition.  
The execution time for commands depends on other  
processes running inside the TPU firmware, therefore  
the host controller has to read the status register to get  
information about the running command before read-  
ing command parameter or starting other commands.  
3.14.1.2. DRAM Subaddressing  
DRAM access is necessary to generate level 2 dis-  
plays. The external DRAM can be addressed on byte  
level. The maximum DRAM size of 16 Mbit requires a  
21-bit memory address pointer. The format of the  
DRAM address pointer is shown in Fig. 3–20.  
The status register returns information about the com-  
mand interface. The ‘command wait’ bit is set during  
execution of a command and is reset when a com-  
mand is executed completely and read parameters are  
available. If a non-existing command is sent to the  
TPU, the ‘command invalid’ bit is set. If a command  
could not be executed successfully, the ‘command  
found no data’ bit is set. In this case the read parame-  
ters of this command are not valid.  
5-bit Bank  
8-bit High  
8-bit Low  
Fig. 3–20: DRAM address pointer  
Reading status from TPU is done by subaddressing  
the status register followed by repeated start condition  
and slave read address (see Fig. 3–21).  
The DRAM subaddress has to be followed by  
3 address bytes defining the DRAM address pointer.  
The following data byte is written into this address.  
< 22 7B cc dd ..  
< 22 7D < 23 ss .. >  
< 22 7C < 23 dd .. >  
>
DRAM subaddressing always uses autoincrement.  
Separate read and write DRAM address pointers are  
saved for autoincrement.  
Telegrams subaddressing the command interface are  
buffered and processed after receiving the stop condi-  
tion. Therefore the command code and all necessary  
command parameters have to be included in a single  
telegram.  
The DRAM telegram can be stopped after the 3 ad-  
dress pointer bytes. The following I2C telegram subad-  
dressing the data register will continue data transfer to  
or from the DRAM.  
When reading the DRAM, the first data byte the TPU  
returns is a dummy byte, which has to be ignored.  
3.14.1.4. Data Subaddressing  
Writing data to TPU memory is possible by subad-  
dressing the data register directly. The data is then  
written into memory addressed by the foregoing tele-  
gram.  
< 22 7A ab ah al dd .. >  
< 22 7A ab ah al > < 22 7C dd .. >  
< 22 7A ab ah al > < 22 7C < 23 dd ..>  
Data written to the DRAM subaddress is collected first  
in the I2C buffer of TPU and is copied to DRAM when  
the buffer is full (48 Bytes) or after stop condition. Dur-  
ing the time the buffer is copied to DRAM the TPU will  
hold the I2C clock line down.  
< 22 7C dd .. >  
Reading data from TPU is done by subaddressing the  
data register followed by a repeated start condition and  
slave read address (see Fig. 3–21). The returned data  
depend on the subaddress selected in the preceding  
TPU telegram.  
Reading data from the DRAM subaddress is also buff-  
ered internally. Reading the first byte will only empty the  
I2C buffer. Every time the buffer is empty, the TPU will  
copy 48 Bytes from DRAM into the I2C buffer. During  
this time the TPU will hold the I2C clock line down.  
< 22 7C < 23 dd .. >  
Micronas  