DATA SHEET  
HAL810  
5.5. Register Information  
MIN-DUTY  
ADC-READOUT  
– This register is read only.  
– The register range is from 8192 up to 8191.  
The register range is from 0 up to 1023.  
– The register value is calculated with:  
Min-Duty  
5.6. Programming Information  
MIN-DUTY =  
* 2048  
If the content of any register (except the lock registers)  
is to be changed, the desired value must first be writ-  
ten into the corresponding RAM register. Before read-  
ing out the RAM register again, the register value must  
be permanently stored in the EEPROM.  
100%  
MAX-DUTY  
– The register range is from 0 up to 2047.  
– The register value is calculated with:  
Max-Duty  
Permanently storing a value in the EEPROM is done  
by first sending an ERASE command followed by  
sending a PROM command. The address within the  
ERASE and PROM commands is not important.  
ERASE and PROM act on all registers in parallel.  
MAX-DUTY =  
* 2048  
100%  
If all HAL810 registers are to be changed, all writing  
commands can be sent one after the other, followed by  
sending one ERASE and PROM command at the end.  
DCOQ  
– The register range is from 1024 up to 1023.  
– The register value is calculated with:  
DCOQ  
During all communication sequences, the customer  
has to check if the communication with the sensor was  
successful. This means that the acknowledge and the  
parity bits sent by the sensor have to be checked by  
the customer. If the Micronas programmer board is  
used, the customer has to check the error flags sent  
from the programmer board.  
DCOQ =  
* 1024  
100%  
DCSENSITIVITY  
Note: For production and qualification tests, it is man-  
datory to set the LOCK bit after final adjustment  
and programming of HAL810. The LOCK func-  
tion is active after the next power-up of the sen-  
sor. Micronas also recommends sending an  
additional ERASE command after sending the  
LOCK command.  
– The register range is from 8192 up to 8191.  
– The register value is calculated with:  
DCSENSITIVITY = DCSensitivity * 2048  
The success of the Lock Process should be  
checked by reading at least one sensor register  
after locking and/or by an analog check of the  
sensors output signal.  
Electrostatic Discharges (ESD) may disturb the  
programming pulses. Please take precautions  
against ESD.  
TC and TCSQ  
– The TC register range is from 31 up to 31.  
– The TCSQ register range is from 0 up to 31.  
Please refer Section 4.3. on page 23 for the recom-  
mended values.  
MODE  
– The register range is from 0 up to 63 and contains  
the settings for FILTER and RANGE:  
MODE = FILTER * 8 + RANGE  
Please refer Section 2.2. on page 8 for the available  
FILTER and RANGE values.  
Micronas  
Feb. 6, 2009; DSH000034_003EN  
29  