 浏览型号PC28F00BP30EFA的Datasheet PDF文件第21页浏览型号PC28F00BP30EFA的Datasheet PDF文件第22页浏览型号PC28F00BP30EFA的Datasheet PDF文件第23页浏览型号PC28F00BP30EFA的Datasheet PDF文件第24页浏览型号PC28F00BP30EFA的Datasheet PDF文件第26页浏览型号PC28F00BP30EFA的Datasheet PDF文件第27页浏览型号PC28F00BP30EFA的Datasheet PDF文件第28页浏览型号PC28F00BP30EFA的Datasheet PDF文件第29页  
P30-65nm  
Read SR command (70h), which would be interpreted by the internal state machine as  
Buffer Word Count.  
On the next write, a word count is written to the device at the buffer address. This tells  
the device how many data words will be written to the buffer, up to the maximum size  
of the buffer.  
On the next write, a device start address is given along with the first data to be written  
to the flash memory array. Subsequent writes provide additional device addresses and  
data. All data addresses must lie within the start address plus the word count.  
Optimum programming performance and lower power usage are obtained by aligning  
the starting address at the beginning of a 512-word boundary (A[9:1] = 0x000). The  
maximum buffer size would be 256-word if the misaligned address range is crossing a  
512-word boundary during programming.  
After the last data is written to the buffer, the Buffered Programming Confirm command  
must be issued to the original block address. The WSM begins to program buffer  
contents to the flash memory array. If a command other than the Buffered  
Programming Confirm command is written to the device, a command sequence error  
occurs and SR[7,5,4] are set. If an error occurs while writing to the array, the device  
stops programming, and SR[7,4] are set, indicating a programming failure.  
When Buffered Programming has completed, additional buffer writes can be initiated by  
issuing another Buffered Programming Setup command and repeating the buffered  
program sequence. Buffered programming may be performed with VPP = VPPL or VPPH  
(see Section 13.2, “Operating Conditions” on page 46 for limitations when operating  
the device with VPP = VPPH).  
If an attempt is made to program past an erase-block boundary using the Buffered  
Program command, the device aborts the operation. This generates a command  
sequence error, and SR[5,4] are set.  
If Buffered programming is attempted while VPP is at or below VPPLK, SR[4,3] are set.  
If any errors are detected that have set Status Register bits, the Status Register should  
be cleared using the Clear Status Register command.  
8.3  
Buffered Enhanced Factory Programming  
Buffered Enhanced Factory Programing (BEFP) speeds up Multi-Level Cell (MLC) flash  
programming. The enhanced programming algorithm used in BEFP eliminates  
traditional programming elements that drive up overhead in device programmer  
systems.  
BEFP consists of three phases: Setup, Program/Verify, and Exit (see Figure 33, “BEFP  
Flowchart” on page 75). It uses a write buffer to spread MLC program performance  
across 512 data words. Verification occurs in the same phase as programming to  
accurately program the flash memory cell to the correct bit state.  
A single two-cycle command sequence programs the entire block of data. This  
enhancement eliminates three write cycles per buffer: two commands and the word  
count for each set of 512 data words. Host programmer bus cycles fill the device’s write  
buffer followed by a status check. SR.0 indicates when data from the buffer has been  
programmed into sequential flash memory array locations.  
Following the buffer-to-flash array programming sequence, the Write State Machine  
(WSM) increments internal addressing to automatically select the next 512-word array  
boundary. This aspect of BEFP saves host programming equipment the address-bus  
setup overhead.  
Datasheet  
25  
Sept 2012  
OrderNumber:208042-06  
 复制成功!