128Mb 3V Embedded Parallel NOR Flash  
Program Operations  
Program Operations  
PROGRAM Command  
The PROGRAM (A0h) command can be used to program a value to one address in the  
memory array. The command requires four bus WRITE operations, and the final WRITE  
operation latches the address and data in the internal state machine and starts the pro-  
gram/erase controller. After programming has started, bus READ operations output the  
status register content.  
Programming can be suspended and then resumed by issuing a PROGRAM SUSPEND  
command and a PROGRAM RESUME command, respectively.  
If the address falls in a protected block, the PROGRAM command is ignored, and the  
data remains unchanged. The status register is not read, and no error condition is given.  
After the PROGRAM operation has completed, the device returns to read mode, unless  
an error has occurred. When an error occurs, bus READ operations to the device contin-  
ue to output the status register. A READ/RESET command must be issued to reset the  
error condition and return the device to read mode.  
The PROGRAM command cannot change a bit set to 0 back to 1, and an attempt to do  
so is masked during a PROGRAM operation. Instead, an ERASE command must be used  
to set all bits in one memory block or in the entire memory from 0 to 1.  
The PROGRAM operation is aborted by performing a reset or by powering-down the de-  
vice. In this case, data integrity cannot be ensured, and it is recommended that the  
words or bytes that were aborted be reprogrammed.  
UNLOCK BYPASS PROGRAM Command  
When the device is in unlock bypass mode, the UNLOCK BYPASS PROGRAM (A0h)  
command can be used to program one address in the memory array. The command re-  
quires two bus WRITE operations instead of four required by a standard PROGRAM  
command; the final WRITE operation latches the address and data and starts the pro-  
gram/erase controller (The standard PROGRAM command requires four bus WRITE op-  
erations). The PROGRAM operation using the UNLOCK BYPASS PROGRAM command  
behaves identically to the PROGRAM operation using the PROGRAM command. The  
operation cannot be aborted. A bus READ operation to the memory outputs the status  
register.  
WRITE TO BUFFER PROGRAM Command  
The WRITE TO BUFFER PROGRAM (25h) command makes use of the 32-word program  
buffer to speed up programming. A maximum of 32 words can be loaded into the pro-  
gram buffer. The WRITE TO BUFFER PROGRAM command dramatically reduces system  
programming time compared to the standard non-buffered PROGRAM command.  
When issuing a WRITE TO BUFFER PROGRAM command, V PP/WP# can be either held  
HIGH or raised to VPPH. Also, it can be held LOW if the block is not the lowest or highest  
block, depending on the part number. The following successive steps are required to is-  
sue the WRITE TO BUFFER PROGRAM command:  
First, two UNLOCK cycles are issued. Next, a third bus WRITE cycle sets up the WRITE  
TO BUFFER PROGRAM command. The set-up code can be addressed to any location  
PDF: 09005aef84daa141  
m29w_128mb.pdf - Rev. A 7/13 EN  
Micron Technology, Inc. reserves the right to change products or specifications without notice.  