M25P128
DC and AC parameters
10
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 11.
Symbol
Operating conditions
Parameter
Min.
Typ.
Max.
Unit
VCC
VPPH
TA
Supply Voltage
2.7
3.6
V
Supply Voltage on W/VPP pin for Fast
Program/Erase mode
8.5
–40
15
9.5
85
35
V
Ambient Operating Temperature
°C
°C
Ambient Operating Temperature for Fast
Program/Erase mode
TAVPP
25
30
Table 12. AC measurement conditions
Symbol
Parameter
Load Capacitance
Min.
Max.
Unit
CL
pF
ns
V
Input Rise and Fall Times
5
Input Pulse Voltages
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
VCC / 2
Input Timing Reference Voltages
Output Timing Reference Voltages
V
V
1. Output Hi-Z is defined as the point where data out is no longer driven.
Figure 19. AC measurement I/O waveform
Input Levels
Input and Output
Timing Reference Levels
0.8V
CC
0.7V
0.5V
0.3V
CC
CC
CC
0.2V
CC
AI07455
Table 13. Capacitance
Symbol
Parameter
Test Condition
Min.
Max.
Unit
COUT
CIN
Output Capacitance (Q)
VOUT = 0V
VIN = 0V
8
6
pF
pF
Input Capacitance (other pins)
1. Sampled only, not 100% tested, at TA=25 °C and a frequency of 20 MHz.
35/47