欢迎访问ic37.com |
会员登录 免费注册
发布采购

PIC18F4520-I/PT 参数 Datasheet PDF下载

PIC18F4520-I/PT图片预览
型号: PIC18F4520-I/PT
PDF下载: 下载PDF文件 查看货源
内容描述: 28 /40/ 44引脚增强型闪存微控制器与10位A / D和纳瓦技术 [28/40/44-Pin Enhanced Flash Microcontrollers with 10-Bit A/D and nanoWatt Technology]
分类和应用: 闪存微控制器
文件页数/大小: 412 页 / 6898 K
品牌: MICROCHIP [ MICROCHIP ]
 浏览型号PIC18F4520-I/PT的Datasheet PDF文件第189页浏览型号PIC18F4520-I/PT的Datasheet PDF文件第190页浏览型号PIC18F4520-I/PT的Datasheet PDF文件第191页浏览型号PIC18F4520-I/PT的Datasheet PDF文件第192页浏览型号PIC18F4520-I/PT的Datasheet PDF文件第194页浏览型号PIC18F4520-I/PT的Datasheet PDF文件第195页浏览型号PIC18F4520-I/PT的Datasheet PDF文件第196页浏览型号PIC18F4520-I/PT的Datasheet PDF文件第197页  
PIC18F2420/2520/4420/4520  
17.4.10 I2C MASTER MODE  
TRANSMISSION  
17.4.10.3 ACKSTAT Status Flag  
In Transmit mode, the ACKSTAT bit (SSPCON2<6>) is  
cleared when the slave has sent an Acknowledge  
(ACK = 0) and is set when the slave does not Acknowl-  
edge (ACK = 1). A slave sends an Acknowledge when  
it has recognized its address (including a general call),  
or when the slave has properly received its data.  
Transmission of a data byte, a 7-bit address or the  
other half of a 10-bit address is accomplished by simply  
writing a value to the SSPBUF register. This action will  
set the Buffer Full flag bit, BF, and allow the Baud Rate  
Generator to begin counting and start the next trans-  
mission. Each bit of address/data will be shifted out  
onto the SDA pin after the falling edge of SCL is  
asserted (see data hold time specification  
parameter 106). SCL is held low for one Baud Rate  
Generator rollover count (TBRG). Data should be valid  
before SCL is released high (see data setup time spec-  
ification parameter 107). When the SCL pin is released  
high, it is held that way for TBRG. The data on the SDA  
pin must remain stable for that duration and some hold  
time after the next falling edge of SCL. After the eighth  
bit is shifted out (the falling edge of the eighth clock),  
the BF flag is cleared and the master releases SDA.  
This allows the slave device being addressed to  
respond with an ACK bit during the ninth bit time if an  
address match occurred, or if data was received prop-  
erly. The status of ACK is written into the ACKDT bit on  
the falling edge of the ninth clock. If the master receives  
an Acknowledge, the Acknowledge Status bit,  
ACKSTAT, is cleared. If not, the bit is set. After the ninth  
clock, the SSPIF bit is set and the master clock (Baud  
Rate Generator) is suspended until the next data byte  
is loaded into the SSPBUF, leaving SCL low and SDA  
unchanged (Figure 17-21).  
17.4.11 I2C MASTER MODE RECEPTION  
Master mode reception is enabled by programming the  
Receive Enable bit, RCEN (SSPCON2<3>).  
Note:  
The MSSP module must be in an Idle state  
before the RCEN bit is set or the RCEN bit  
will be disregarded.  
The Baud Rate Generator begins counting and on each  
rollover, the state of the SCL pin changes (high-to-low/  
low-to-high) and data is shifted into the SSPSR. After  
the falling edge of the eighth clock, the receive enable  
flag is automatically cleared, the contents of the  
SSPSR are loaded into the SSPBUF, the BF flag bit is  
set, the SSPIF flag bit is set and the Baud Rate Gener-  
ator is suspended from counting, holding SCL low. The  
MSSP is now in Idle state awaiting the next command.  
When the buffer is read by the CPU, the BF flag bit is  
automatically cleared. The user can then send an  
Acknowledge bit at the end of reception by setting the  
Acknowledge Sequence Enable bit, ACKEN  
(SSPCON2<4>).  
17.4.11.1 BF Status Flag  
After the write to the SSPBUF, each bit of the address  
will be shifted out on the falling edge of SCL until all  
seven address bits and the R/W bit are completed. On  
the falling edge of the eighth clock, the master will  
deassert the SDA pin, allowing the slave to respond  
with an Acknowledge. On the falling edge of the ninth  
clock, the master will sample the SDA pin to see if the  
address was recognized by a slave. The status of the  
ACK bit is loaded into the ACKSTAT status bit  
(SSPCON2<6>). Following the falling edge of the ninth  
clock transmission of the address, the SSPIF is set, the  
BF flag is cleared and the Baud Rate Generator is  
turned off until another write to the SSPBUF takes  
place, holding SCL low and allowing SDA to float.  
In receive operation, the BF bit is set when an address  
or data byte is loaded into SSPBUF from SSPSR. It is  
cleared when the SSPBUF register is read.  
17.4.11.2 SSPOV Status Flag  
In receive operation, the SSPOV bit is set when 8 bits  
are received into the SSPSR and the BF flag bit is  
already set from a previous reception.  
17.4.11.3 WCOL Status Flag  
If the user writes the SSPBUF when a receive is  
already in progress (i.e., SSPSR is still shifting in a data  
byte), the WCOL bit is set and the contents of the buffer  
are unchanged (the write doesn’t occur).  
17.4.10.1 BF Status Flag  
In Transmit mode, the BF bit (SSPSTAT<0>) is set  
when the CPU writes to SSPBUF and is cleared when  
all 8 bits are shifted out.  
17.4.10.2 WCOL Status Flag  
If the user writes the SSPBUF when a transmit is  
already in progress (i.e., SSPSR is still shifting out a  
data byte), the WCOL is set and the contents of the  
buffer are unchanged (the write doesn’t occur).  
WCOL must be cleared in software.  
© 2008 Microchip Technology Inc.  
DS39631E-page 191  
 复制成功!