dsPIC33F/PIC24H PROGRAMMING SPECIFICATION
TABLE 5-11: SERIAL INSTRUCTION EXECUTION FOR READING THE APPLICATION ID WORD
Command
(Binary)
Data
(Hex)
Description
Step 1: Exit Reset vector.
0000
0000
0000
0000
000000
000000
040200
000000
NOP
NOP
GOTO
NOP
0x200
Step 2: Initialize TBLPAG and the read pointer (W0) for TBLRDinstruction.
0000
0000
0000
0000
0000
0000
0000
0000
200800
880190
205FE0
207841
000000
BA0890
000000
000000
MOV
MOV
MOV
MOV
NOP
#0x80, W0
W0, TBLPAG
#0x5BE, W0
#VISI, W1
TBLRDL [W0], [W1]
NOP
NOP
Step 3: Output the VISI register using the REGOUTcommand.
0001
<VISI>
Clock out contents of the VISI register
© 2007 Microchip Technology Inc.
Preliminary
DS70152D-page 67