 浏览型号ATMEGA16M1-15MZ的Datasheet PDF文件第304页浏览型号ATMEGA16M1-15MZ的Datasheet PDF文件第305页浏览型号ATMEGA16M1-15MZ的Datasheet PDF文件第306页浏览型号ATMEGA16M1-15MZ的Datasheet PDF文件第307页浏览型号ATMEGA16M1-15MZ的Datasheet PDF文件第309页浏览型号ATMEGA16M1-15MZ的Datasheet PDF文件第310页浏览型号ATMEGA16M1-15MZ的Datasheet PDF文件第311页浏览型号ATMEGA16M1-15MZ的Datasheet PDF文件第312页  
Figure 30-1. The Break Field  
Frame  
Header  
Response  
Response space  
Break  
field  
Sync  
field  
Protected  
identifier  
field  
Data 1  
Data 2  
Data N  
Checksum  
Inter-byte space  
Inter-byte space  
Break  
delimiter  
Break  
Workaround  
None  
8. ADC measurement reports abnormal values with PSC2-synchronized conversions  
When using ADC in synchronized mode, an unexpected extra Single ended conversion can spuriously re-start.  
This can occur when the End of conversion and the Trigger event occur at the same time.  
Workaround  
No workaround  
9. ADC amplifier measurement is unstable  
When switching from a single-ended ADC channel to an amplified channel, noise can appear on the next ADC  
conversion.  
Workaround  
After switching from a single ended to an amplified channel, discard the first ADC conversion.  
10. PSC emulation  
In emulation mode, TCNTn, OCRnx and ICRn 16-bit registers are accessed via the TEMP register. This can  
induce an execution error, in step by step mode due to TEMP register corruption.  
Workaround  
No workaround  
11. PSC OCRxx Register Update according to PLOCK2 Usage  
If the PSC is clocked from PLL, and if PLOCK2 bit is changed at the same time as PSC end of cycle occurs, and if  
OCRxx registers contents have been changed, then the updated OCRxx registers contents are not predictable.  
The cause is a synchronization issue between two registers in two different clock domains (PLL clock which  
clocks PSC and CPU clock).  
Workaround  
Enable the PSC end of cycle interrupt.  
At the beginning of PSC EOC interrupt vector, change PLOCK value (OCRxx registers can be updated outside the  
interrupt vector).  
This process guarantees that UPDATE and PLOCK actions will not occur at the same moment.  
12. Read / Write instructions of MUXn and REFS1:0 bits in the ADMUX Register during Analog conversion  
during Analog conversion, the set or clear instructions of ADMUX channel and reference selection bits will fail.The  
bits of the temporary buffer will be written in place of the final bits.  
Workaround  
Wait for the end of ADC conversion before any write of new channel or reference selection values in ADMUX.  
308  