24AA65/24LC65/24C65  
3.6  
Device Addressing  
4.0  
4.1  
WRITE OPERATION  
Byte Write  
A control byte is the first byte received following the  
Start condition from the master device. The control byte  
consists of a four-bit control code, for the 24XX65 this  
is set as ‘1010’ binary for read and write operations.  
The next three bits of the control byte are the device  
select bits (A2, A1, A0). They are used by the master  
device to select which of the eight devices are to be  
accessed. These bits are in effect the three Most  
Significant bits of the word address. The last bit of the  
control byte defines the operation to be performed.  
When set to a one a read operation is selected, when  
set to a zero a write operation is selected. The next two  
bytes received define the address of the first data byte  
(Figure 4-1). Because only A12..A0 are used, the  
upper three address bits must be zeros. The Most  
Significant bit of the Most Significant Byte is transferred  
first. Following the Start condition, the 24XX65  
monitors the SDA bus checking the device type  
identifier being transmitted. Upon receiving a ‘1010’  
code and appropriate device select bits, the slave  
device (24XX65) outputs an Acknowledge signal on the  
SDA line. Depending upon the state of the R/W bit, the  
24XX65 will select a read or write operation.  
Following the Start condition from the master, the con-  
trol code (four bits), the device select (three bits), and  
the R/W bit which is a logic low, is placed onto the bus  
by the master transmitter. This indicates to the  
addressed slave receiver (24XX65) that a byte with a  
word address will follow after it has generated an  
Acknowledge bit during the ninth clock cycle. There-  
fore, the next byte transmitted by the master is the  
high-order byte of the word address and will be written  
into the address pointer of the 24XX65. The next byte  
is the Least Significant Address Byte. After receiving  
another Acknowledge signal from the 24XX65, the  
master device will transmit the data word to be written  
into the addressed memory location. The 24XX65  
acknowledges again and the master generates a Stop  
condition. This initiates the internal write cycle, and  
during this time the 24XX65 will not generate  
Acknowledge signals (Figure 4-1).  
4.2  
Page Write  
The write control byte, word address and the first data  
byte are transmitted to the 24XX65 in the same way as  
in a byte write. But instead of generating a Stop  
condition, the master transmits up to eight pages of  
eight data bytes each (64 bytes total), which are  
temporarily stored in the on-chip page cache of the  
24XX65. They will be written from the cache into the  
EEPROM array after the master has transmitted a Stop  
condition. After the receipt of each word, the six lower  
order address pointer bits are internally incremented by  
one. The higher order seven bits of the word address  
remain constant. If the master should transmit more  
than eight bytes prior to generating the Stop condition  
(writing across a page boundary), the address counter  
(lower three bits) will roll over and the pointer will be  
incremented to point to the next line in the cache. This  
can continue to occur up to eight times or until the cache  
is full, at which time a Stop condition should be  
generated by the master. If a Stop condition is not  
received, the cache pointer will roll over to the first line  
(byte 0) of the cache, and any further data received will  
overwrite previously captured data. The Stop condition  
can be sent at any time during the transfer. As with the  
byte write operation, once the Stop condition is received  
an internal write cycle will begin. The 64-byte cache will  
continue to capture data until a Stop condition occurs or  
the operation is aborted (Figure 4-2).  
Operation Control Code Device Select R/W  
Read  
Write  
1010  
1010  
Device Address  
DeviceAddress  
1
0
FIGURE 3-2:  
CONTROL BYTE  
ALLOCATION  
START  
READ/WRITE  
SLAVE ADDRESS  
R/W  
A
1
0
1
0
A2  
A1  
A0  