MX29LV640BT/BB
AC CHARACTERISTICS
Read-Only Operations
Parameter
TA=-40°C to 85°C, VCC=2.7V~3.6V
Speed Options
Std.
tRC
tACC
tCE
tOE
tDF
Description
Test Setup
90
90
90
90
35
30
30
120
120
120
120
50
Unit
ns
ns
ns
ns
ns
ns
ns
Read CycleTime (Note 1)
Min
CE#, OE#=VIL Max
Address to Output Delay
Chip Enable to Output Delay
Output Enable to Output Delay
Chip Enable to Output High Z (Note 1)
Output Enable to Output High Z (Note 1)
Output Hold Time From Address, CE#
or OE#, whichever Occurs First
Read
OE#=VIL
Max
Max
Max
Max
Min
30
tDF
30
tOH
0
Min
Min
0
ns
ns
tOEH
Output Enable HoldTime Toggle and
10
(Note 1)
Data# Polling
Notes:
1. Not 100% tested.
2. See SWITCHING TEST CIRCUITS and TEST SPECIFICATIONS TABLE for test specifications.
P/N:PM1076
REV. 1.2, SEP. 07, 2005
35