78M6610+LMU Data Sheet  
Command Register  
The Command Register is located at address 0x00. Use this register to perform specific tasks such as  
saving coefficients and nonvolatile register defaults into flash memory. It also allows initiation of  
integrated calibration routines.  
Value (hex)  
00xxxx  
Description  
Normal operation  
Calibration commands  
Software reset  
CAxxxx  
BDxxxx  
ACCxxx  
Flash access commands  
Normal Operation  
The general settings command allows the user to enable functions such as UART auto reporting, relay  
operations, and Line Lock mode etc.  
Bit(s)  
23:16  
5
Value  
0x00  
LL  
Description  
“General settings” command used during normal operation.  
Line Lock 1 = lock to line cycle; 0 = independent.  
4
TC  
Enable Die Temperature (Gain) Compensation 1 = enable; 0 = disable (Debug  
Only)  
Calibration Command  
The Calibration Command starts the calibration process for the selected inputs. It is assumed that  
appropriate input signals are applied. When the calibration process completes, bits 23:16 are cleared  
along with bits associated with channels that calibrated successfully. When calibrating gain, any channels  
that failed will have their corresponding bit left set. When calibrating offset, the bit corresponding to the  
selected channels will remain set.  
Bit(s)  
23:16  
14  
Value  
0xCA  
S2  
Description  
“Calibrate” Command.  
Calibrate Voltage for Sensor 2.  
Calibrate Voltage for Sensor 0.  
Calibrate Current for Sensor 3.  
Calibrate Current for Sensor 1.  
Calibrate Temperature.  
13  
S0  
12  
S3  
11  
S1  
10  
T
9
O
Calibrate Offset ( = 1) or Gain ( = 0).  
Lock Sample Period to Line Cycle.  
5
LL  
4
TC  
Enable Die Temperature (Gain) Compensation 1 = enable; 0 = disable  
(debug only)  
NOTE: During calibration, the “line-lock” bit should be set for best results.  
42  
Rev 0  
 
 
 