71M6543F/H and 71M6543G/GH Data Sheet
Bit
Symbol
TB80
Function
S0CON[3]
The 9th transmitted data bit in Modes 2 and 3. Set or cleared by the MPU,
depending on the function it performs (parity check, multiprocessor
communication etc.)
In Modes 2 and 3 it is the 9th data bit received. In Mode 1, SM20 is 0, RB80 is the
S0CON[2]
S0CON[1]
S0CON[0]
RB80
TI0
stop bit. In mode 0, this bit is not used. Must be cleared by software.
Transmit interrupt flag; set by hardware after completion of a serial transfer. Must
be cleared by software (see Caution above).
RI0
Receive interrupt flag; set by hardware after completion of a serial reception. Must
be cleared by software (see Caution above).
Table 20: The S1CON (UART1) Register (SFR 0x9B)
Bit
Symbol
Function
S1CON[7]
SM
Sets the baud rate and mode for UART1.
Mode
Description
9-bit UART
8-bit UART
Baud Rate
variable
SM
0
A
B
1
variable
S1CON[5]
S1CON[4]
S1CON[3]
SM21
REN1
TB81
Enables the inter-processor communication feature.
If set, enables serial reception. Cleared by software to disable reception.
The 9th transmitted data bit in Mode A. Set or cleared by the MPU, depending
on the function it performs (parity check, multiprocessor communication etc.)
In Modes A and B, it is the 9th data bit received. In Mode B, if SM21 is 0, RB81 is
S1CON[2]
S1CON[1]
S1CON[0]
RB81
TI1
the stop bit. Must be cleared by software
Transmit interrupt flag, set by hardware after completion of a serial transfer. Must
be cleared by software (see Caution above).
RI1
Receive interrupt flag, set by hardware after completion of a serial reception. Must
be cleared by software (see Caution above).
Table 21: PCON Register Bit Description (SFR 0x87)
Bit
Symbol
SMOD
Function
PCON[7]
The SMOD bit doubles the baud rate when set
2.4.7 Timers and Counters
The 80515 has two 16-bit timer/counter registers: Timer 0 and Timer 1. These registers can be configured
for counter or timer operations.
In timer mode, the register is incremented every machine cycle, i.e. it counts up once for every 12 periods of
the MPU clock. In counter mode, the register is incremented when the falling edge is observed at the
corresponding input signal T0 or T1 (T0 and T1 are the timer gating inputs derived from certain DIO pins, see
2.5.10 Digital I/O). Since it takes 2 machine cycles to recognize a 1-to-0 event, the maximum input count rate
is 1/2 of the clock frequency (CKMPU). There are no restrictions on the duty cycle, however to ensure proper
recognition of the 0 or 1 state, an input should be stable for at least 1 machine cycle.
Four operating modes can be selected for Timer 0 and Timer 1, as shown in Table 22 and Table 23. The
TMOD (SFR 0x89) register, shown in
Table 24, is used to select the appropriate mode. The timer/counter operation is controlled by the TCON
(SFR 0x88) register, which is shown in Table 25. Bits TR1 (TCON[6]) and TR0 (TCON[4]) in the TCON
register start their associated timers when set.