 浏览型号MAS6505BA1Q1706的Datasheet PDF文件第15页浏览型号MAS6505BA1Q1706的Datasheet PDF文件第16页浏览型号MAS6505BA1Q1706的Datasheet PDF文件第17页浏览型号MAS6505BA1Q1706的Datasheet PDF文件第18页浏览型号MAS6505BA1Q1706的Datasheet PDF文件第20页浏览型号MAS6505BA1Q1706的Datasheet PDF文件第21页浏览型号MAS6505BA1Q1706的Datasheet PDF文件第22页浏览型号MAS6505BA1Q1706的Datasheet PDF文件第23页  
DA6505.005  
11 June 2018  
CONTROL REGISTER (EF/6FHEX  
)
The  
Control  
register  
(EF/6FHEX  
)
contains  
See ELECTRICAL CHARACTERISTICS on pages  
3-7.  
measurement and operating mode selection  
settings. Writing to Control register starts the  
selected measurements. See table 4.  
The MODE bits select from three operating modes.  
The MODE=00 setting selects sleep mode in which  
there are no measurements performed and only a  
very small sleep current is drawn from the supplies.  
There are oversampling ratio (OSR) settings for  
temperature and pressure. The OSRT setting is for  
temperature and OSRP for pressure measurement.  
Each of them has seven settings 1/4x, 1/2x, 1x, 2x,  
4x, 8x and 16x in addition to no measurement  
setting. Thus it is possible select only temperature or  
pressure measurement or both measurements. The  
oversampling ratio setting affects measurement  
resolution and speed and power consumption. The  
highest value setting gives the highest resolution but  
it has the longest A/D conversion time and the  
highest power consumption. Similar way the lowest  
value setting gives the lowest resolution but it has  
the shortest A/D conversion time and the lowest  
power consumption. Thus the multiple oversampling  
ratio settings allow optimizing measurements  
between speed, power consumption and resolution.  
The MODE=01 or 10 setting selects forced mode  
which runs selected measurements only once after  
which the device returns automatically to the sleep  
mode.  
The MODE=11 setting selects normal mode in which  
selected  
measurements  
are  
performed  
automatically in  
a
loop. The delay between  
measurements is configured by DELAY bit setting in  
the Configuration register (EE/6EHEX). To minimize  
current consumption the device enters standby  
mode for the time between measurements during  
which only the internal clock oscillator is running.  
The automatic measurements are stopped by setting  
MODE=00 which selects the sleep mode.  
Table 4. Control register (EF/6FHEX) description  
Bit  
Bit  
Description  
Value  
Function  
Number  
Name  
7-5  
4-2  
1-0  
OSRT  
Oversampling ratio  
for temperature  
measurement  
000  
001  
010  
011  
100  
101  
110  
111  
000  
001  
010  
011  
100  
101  
110  
111  
00  
No temperature measurement (default)  
1/4x Very fast mode  
1/2x Fast mode  
1x Ultra low power  
2x Low power  
4x Standard resolution  
8x High resolution  
16x Ultra high resolution  
No pressure measurement (default)  
1/4x Very fast mode  
1/2x Fast mode  
1x Ultra low power  
2x Low power  
4x Standard resolution  
8x High resolution  
16x Ultra high resolution  
OSRP  
Oversampling ratio  
for pressure  
measurement  
MODE Operating mode  
Sleep mode (default)  
01, 10 Forced mode (single command based measurement)  
11 Normal mode (automated measurements)  
19 (44)  