DA6116.010
5 October, 2017
ABSOLUTE MAXIMUM RATINGS
All voltages with respect to ground.
Parameter
Symbol
Conditions
Min
Max
Unit
Signal Voltage
RIN, RFO, LIN, LFO
AVCC, DVCC
-20
-0.5
-0.3
+20
V
V
V
Positive Supply Voltage
All other pins
+6.0
DATA, CLK, XCS,
Note 2.
AVCC
+0.3
XMUTE
Storage Temperature
Operating Temperature
TS
-55
-40
500
+125
oC
oC
V
TA
+95
ESD Rating
(JEDEC JS-001-2017)
VHBM
Pins 3 (LFO), 4 (LIN), 13
(RIN) and 14 (RFO)
All other pins
1000
Note 2. Pin voltage must not exceed +6V under any circumstances.
Operation at maximum conditions will not damage the part but performance cannot be guaranteed. Stresses beyond those listed may cause
permanent damage to the device.
RECOMMENDED OPERATION CONDITIONS
(AVCC=+5.0 V, AGND=0 V, TA=+25oC unless otherwise noted)
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Signal Voltage
RIN, RFO, LIN, LFO
RMO, LMO
AVCC,DVCC
AGND,DGND
LGND,RGND
TA
-18
-0.1
4.5
+18
+0.1
5.5
V
V
Virtual Ground Voltage
Positive Supply Voltage
Negative Supply Voltage
Signal Grounds
0
5
V
0
V
0
V
Operating Temperature
-30
+25
+85
oC
ANALOG CHARACTERISTICS
Analog Inputs/Outputs
(AVCC=+5.0 V, AGND=0 V, TA=+25oC unless otherwise noted)
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Input impedance
Input capacitance
Input offset voltage
RIN
CIN
VIH
Average impedance, note 3.
For any gain value
7
10
2
13
k
pF
External OpAmp, Gain = 15.5 dB
Note 4.
0.23
mV
Supply current
IVCC
AVCC+DVCC
0.6
80
2.2
mA
dB
Power supply
rejection ratio1
PSRR
From AVCC
Note 3. Average input impedance is calculated as an average of the impedance measured for all gain values.
Note 4. Output offset voltage depends on external opamp and selected gain. Low input offset voltage and input bias current opamp is
recommended to be used for minimum output offset.
10 (20)