General Information
Product Nomenclature
LUXEONꢀMꢀemittersꢀareꢀspecifiedꢀandꢀbinnedꢀ“hot”ꢀunderꢀconditionsꢀcomparableꢀtoꢀthoseꢀfoundꢀinꢀ“real-world”ꢀlightingꢀ
products.ꢀꢀ
Theꢀpartꢀnumberꢀdesignationꢀisꢀexplainedꢀasꢀfollows:
LꢀXꢀRꢀaꢀ-ꢀbꢀcꢀdꢀeꢀ-ꢀfꢀgꢀhꢀj
Where:
aꢀ—ꢀdesignatesꢀminimumꢀCRIꢀ(7ꢀ=ꢀ70,ꢀ8ꢀ=ꢀ80,ꢀ9ꢀ=ꢀ90,ꢀ0ꢀ=ꢀRoyalꢀBlue)
bꢀ—ꢀisꢀSꢀforꢀseriallyꢀconnectedꢀproductꢀwithꢀvoltageꢀlessꢀthanꢀ12V;ꢀRꢀforꢀseries-parallelꢀcollectedꢀproductꢀwithꢀvoltageꢀlessꢀ
ꢀꢀꢀꢀꢀꢀꢀthanꢀ6V.
cꢀ—ꢀdesignatesꢀcolorꢀdesignationꢀ(Wꢀ=ꢀWhite,ꢀRꢀ=ꢀRoyalꢀBlue)ꢀ
d,ꢀeꢀ—ꢀdesignatesꢀCCTꢀ(27ꢀ=ꢀ2700K,ꢀ30ꢀ=ꢀ3000K,ꢀ35ꢀ=ꢀ3500K,ꢀ40ꢀ=ꢀ4000K,ꢀ50ꢀ=ꢀ5000K,ꢀ57ꢀ=ꢀ5700K,ꢀ00ꢀ=ꢀRoyalꢀBlue)
fghjꢀ—ꢀminimumꢀfluxꢀlumenꢀ(optional)ꢀ
Theꢀtestꢀconditionsꢀforꢀ12VꢀLUXEONꢀMꢀLXRa-Scde-fghjꢀareꢀ700mAꢀDCꢀwithꢀjunctionꢀtemperatureꢀ85C.ꢀꢀTheꢀtestꢀconditionꢀ
forꢀ6VꢀLUXEONꢀMꢀLXRa-Rcde-fghjꢀareꢀ1400mAꢀDCꢀwithꢀjunctionꢀtemperatureꢀ85C.
ThereforeꢀLUXEONꢀMꢀ12Vꢀproductsꢀtestedꢀandꢀbinnedꢀatꢀ700ꢀmAꢀfollowꢀtheꢀpartꢀnumberingꢀscheme:ꢀ
LꢀXꢀRꢀ7ꢀ-ꢀSꢀWꢀ3ꢀ0ꢀ-ꢀxꢀxꢀxꢀx
LꢀXꢀRꢀ7ꢀ-ꢀSꢀWꢀ4ꢀ0ꢀ-ꢀxꢀxꢀxꢀx
LꢀXꢀRꢀ7ꢀ-ꢀSꢀWꢀ5ꢀ0ꢀ-ꢀxꢀxꢀxꢀx
LꢀXꢀRꢀ7ꢀ-ꢀSꢀWꢀ5ꢀ7ꢀ-ꢀxꢀxꢀxꢀx
LꢀXꢀRꢀ7ꢀ-ꢀSꢀWꢀ6ꢀ5ꢀ-ꢀxꢀxꢀxꢀx
LꢀXꢀRꢀ8ꢀ-ꢀSꢀWꢀ2ꢀ7ꢀ-ꢀxꢀxꢀxꢀx
LꢀXꢀRꢀ8ꢀ-ꢀSꢀWꢀ3ꢀ0ꢀ-ꢀxꢀxꢀxꢀx
LꢀXꢀRꢀ8ꢀ-ꢀSꢀWꢀ3ꢀ5ꢀ-ꢀxꢀxꢀxꢀx
LꢀXꢀRꢀ8ꢀ-ꢀSꢀWꢀ4ꢀ0ꢀ-ꢀxꢀxꢀxꢀx
LꢀXꢀRꢀ8ꢀ-ꢀSꢀWꢀ5ꢀ0ꢀ-ꢀxꢀxꢀxꢀx
LꢀXꢀRꢀ9ꢀ-ꢀSꢀWꢀ2ꢀ7ꢀ-ꢀxꢀxꢀxꢀx
LꢀXꢀRꢀ9ꢀ-ꢀSꢀWꢀ3ꢀ0ꢀ-ꢀxꢀxꢀxꢀxꢀꢀ
LꢀXꢀRꢀ0ꢀ-ꢀSꢀRꢀ0ꢀ0ꢀ-ꢀxꢀxꢀxꢀx
LUXEONꢀMꢀꢀDatasheetꢀDS103ꢀ20130418ꢀ©2013ꢀPhilipsꢀLumiledsꢀLightingꢀCompany.ꢀꢀꢀ
2