Electrical Characteristics for LUXEON M atTest Current [1],
JunctionTemperature = 85°C for all CCTs and Royal Blue
Table 7.
[1, 2]
ForwardVoltageVf
If = 700 mA
(V)
TypicalTemperature Coefficient of TypicalThermal Resistance Junction
ForwardVoltage [3]
(mV/°C)
toThermal Pad
(°C/W)
Part Number
Minimum
Typical
Maximum
DVF / DTJ
RuJ-C
LXRx-Sxxx
LXRx-Rxxx
10.5
5.44
11.2
5.6
12
-5.5
-5.5
1.25
1.25
5.72
Notes forTable 7:
1.ꢀꢀTestꢀcurrentꢀisꢀ700ꢀmAꢀforꢀLXRx-Sxxxꢀandꢀ1400ꢀmAꢀforꢀLXRx-Rxxxꢀproducts.
2.ꢀꢀPhilipsꢀLumiledsꢀmaintainsꢀaꢀtoleranceꢀofꢀ±ꢀ0.5%ꢀonꢀforwardꢀvoltageꢀmeasurements.
3.ꢀꢀMeasuredꢀbetweenꢀTJꢀ=ꢀꢀ25°CꢀandꢀꢀTJꢀ=ꢀ135°C.
Absolute Maximum Ratings
Table 8.
Parameter
Maximum Performance
DCꢀForwardꢀCurrentꢀ(mA)ꢀ[1],ꢀ[2]
PeakꢀPulsedꢀForwardꢀCurrentꢀ[1],ꢀ[3]
1050ꢀmAꢀforꢀLXRx-Sxxx;ꢀ2100ꢀmAꢀforꢀLXRx-Rxxx
1200ꢀmAꢀforꢀLXRx-Sxxx;ꢀ2400ꢀmAꢀforꢀLXRx-Rxxx
ꢀ
≤ꢀ8000VꢀHumanꢀBodyꢀModelꢀ(HBM)ꢀ
Classꢀ3BꢀJESD22-A114-Eꢀ
ESDꢀSensitivity
<ꢀ400VꢀMachineꢀModelꢀ(MM)ꢀ
ClassꢀBꢀJESD22-A115-B
LEDꢀJunctionꢀTemperatureꢀ[1]
135°C
-40°Cꢀ-ꢀ120°Cꢀ@ꢀ700ꢀmAꢀforꢀLXRx-Sxxxꢀ
-40°Cꢀ-ꢀ120°Cꢀ@1400ꢀmAꢀforꢀLXRx-Rxxxꢀꢀ
OperatingꢀCaseꢀTemperatureꢀatꢀCurrent
StorageꢀTemperatureꢀꢀ
LeadꢀSolderingꢀTemperature
AllowableꢀReflowꢀꢀCycles
-40°Cꢀ-ꢀ120°C
JEDECꢀ020cꢀ260°C
3
121°Cꢀatꢀ2ꢀATMꢀ
100%ꢀRelativeꢀHumidityꢀforꢀ96ꢀHoursꢀMaximum
AutoclaveꢀConditions
ReverseꢀVoltageꢀ(Vr)
LUXEONꢀMꢀLEDsꢀareꢀnotꢀdesignedꢀtoꢀbeꢀdrivenꢀinꢀreverseꢀbias
Notes forTable 8:
1.ꢀꢀProperꢀcurrentꢀderatingꢀmustꢀbeꢀobservedꢀtoꢀmaintainꢀjunctionꢀtemperatureꢀbelowꢀtheꢀmaximum.
2.ꢀꢀResidualꢀperiodicꢀvariationsꢀdueꢀtoꢀpowerꢀconversionꢀfromꢀalternatingꢀcurrentꢀ(AC)ꢀtoꢀdirectꢀcurrentꢀ(DC),ꢀalsoꢀcalledꢀ“ripple”,ꢀwithꢀfrequenciesꢀ≥ꢀ100Hzꢀandꢀꢀ
amplitudeꢀ≤ꢀ1200ꢀmAꢀforꢀLXRx-Sxxxꢀandꢀamplitudeꢀ≤ꢀ2400ꢀmAꢀforꢀLXRx-Rxxxꢀareꢀacceptable,ꢀassumingꢀtheꢀaverageꢀcurrentꢀthroughoutꢀeachꢀcycleꢀdoesꢀnotꢀꢀ
exceedꢀ1050ꢀmAꢀforꢀLXRx-Sxxxꢀandꢀ2100ꢀmAꢀforꢀLXRx-Rxxx.
3.ꢀꢀPulsedꢀoperationꢀwithꢀaꢀpeakꢀdriveꢀcurrentꢀofꢀ1200ꢀmAꢀforꢀLXRx-Sxxxꢀandꢀpeakꢀdriveꢀcurrentꢀofꢀ2400ꢀmAꢀforꢀLXRx-Rxxxꢀisꢀacceptableꢀifꢀtheꢀpulseꢀonꢀtimeꢀꢀ
isꢀ≤ꢀ5msꢀperꢀcycleꢀandꢀtheꢀdutyꢀcycleꢀisꢀ≤ꢀ50%.
JEDEC Moisture Sensitivity
Table 9.
Soak Requirements
Standard
Level
Floor Life
Time
Conditions
Time
Conditions
1
Unlimited
[ꢀ30°Cꢀ/ꢀ85%ꢀRH
168ꢀHrs.ꢀ+ꢀ5ꢀ/ꢀ-0ꢀHrs.
85°Cꢀ/ꢀ85%ꢀRH
LUXEONꢀMꢀꢀDatasheetꢀDS103ꢀ20130418ꢀ©2013ꢀPhilipsꢀLumiledsꢀLightingꢀCompany.ꢀꢀꢀ
7