Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-  
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess  
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended  
periods can adversely affect device reliability.  
Parameter  
Symbol  
Min  
Max  
Unit  
Input Voltage:  
Continuous  
VI  
VI, trans  
80  
100  
Vdc  
V
Transient (100 ms)  
Operating Case Temperature  
TC  
–40  
100  
°C  
(See Thermal Considerations section.)  
Storage Temperature  
I/O Isolation Voltage  
Tstg  
–55  
125  
°C  
1500  
Vdc  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Table 1. Input Specifications  
Parameter  
Operating Input Voltage  
Symbol  
Min  
Typ  
Max  
Unit  
VI  
36  
48  
75  
Vdc  
Maximum Input Current:  
VI = 0 V to 75 V; IO = IO, max:  
JAW050A (See Figure 1.)  
JAW075A (See Figure 2.)  
VI = 36 V to 75 V; IO = IO, max:  
JAW050A  
II, max  
II, max  
3.0  
3.5  
A
A
II, max  
II, max  
1.7  
2.6  
A
A
JAW075A  
Inrush Transient  
i2t  
5
1.0  
A2s  
Input Reflected-ripple Current, Peak-to-peak  
(5 Hz to 20 MHz, 12 µH source impedance;  
see Figure 11.)  
II  
mAp-p  
Input Ripple Rejection (120 Hz)  
60  
dB  
Fusing Considerations  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone  
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-  
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The  
safety agencies require a normal-blow fuse with a maximum rating of 6 A (see Safety Considerations section).  
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same  
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.  