JAW050A and JAW075A Power Modules; dc-dc Converters:  
36 Vdc to 75 Vdc Input, 5 Vdc Output; 50 W to 75 W  
Data Sheet  
April 2008  
Design Considerations  
Input Source Impedance  
Feature Descriptions  
Overcurrent Protection  
The power module should be connected to a low  
ac-impedance input source. Highly inductive source  
impedances can affect the stability of the power mod-  
ule. For the test configuration in Figure 11, a 33 µF  
electrolytic capacitor (ESR < 0.7 Ω at 100 kHz)  
mounted close to the power module helps ensure sta-  
bility of the unit. For other highly inductive source  
impedances, consult the factory for further application  
guidelines.  
To provide protection in an output overload condition,  
the unit is equipped with an internal shutdown and  
auto-restart mechanism. At the instance of current-limit  
inception, the module enters a hiccup mode of opera-  
tion whereby it shuts down and automatically attempts  
to restart. As long as the fault persists, the module  
remains in this mode.  
The protection mechanism is such that the unit can  
continue in this condition until the fault is cleared.  
Safety Considerations  
Remote On/Off  
For safety-agency approval of the system in which the  
power module is used, the power module must be  
installed in compliance with the spacing and separation  
requirements of the end-use safety agency standard,  
i.e., UL 60950, CSA C22.2 No. 60950-00, and  
VDE 0805 (IEC 60950, 4th Edition).  
Two remote on/off options are available. Positive logic  
remote on/off turns the module on during a logic-high  
voltage on the ON/OFF pin, and off during a logic low.  
Negative logic remote on/off turns the module off dur-  
ing a logic high and on during a logic low. Negative  
logic, device code suffix “1,” is the factory-preferred  
configuration.  
If the input source is non-SELV (ELV or a hazardous  
voltage greater than 60 Vdc and less than or equal to  
75 Vdc), for the module's output to be considered  
meeting the requirements of safety extra-low voltage  
(SELV), all of the following must be true:  
To turn the power module on and off, the user must  
supply a switch to control the voltage between the  
on/off terminal and the VI(–) terminal (Von/off). The  
switch can be an open collector or equivalent (see  
Figure 14). A logic low is Von/off = 0 V to 1.2 V. The  
maximum Ion/off during a logic low is 1 mA. The switch  
should maintain a logic-low voltage while sinking 1 mA.  
n The input source is to be provided with reinforced  
insulation from any other hazardous voltages, includ-  
ing the ac mains.  
During a logic high, the maximum Von/off generated by  
the power module is 15 V. The maximum allowable  
leakage current of the switch at Von/off = 15 V is 50 µA.  
n One VI pin and one VO pin are to be grounded, or  
both the input and output pins are to be kept floating.  
n The input pins of the module are not operator acces-  
If not using the remote on/off feature, do one of the  
following:  
sible.  
n Another SELV reliability test is conducted on the  
whole system, as required by the safety agencies, on  
the combination of supply source and the subject  
module to verify that under a single fault, hazardous  
voltages do not appear at the module's output.  
n For negative logic, short the ON/OFF pin to VI(–).  
n For positive logic, leave the ON/OFF pin open.  
Note: Do not ground either of the input pins of the  
module without grounding one of the output  
pins. This may allow a non-SELV voltage to  
appear between the output pins and ground.  
The power module has extra-low voltage (ELV) outputs  
when all inputs are ELV.  
The input to these units is to be provided with a maxi-  
mum 6 A normal-blow fuse in the ungrounded lead.  