Data Sheet  
HC006/010 Series DC-DC Power Module:  
May 16, 2008  
18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are  
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in  
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for  
extended periods can adversely affect the device reliability.  
Parameter  
Device  
All  
Symbol  
VIN  
Min  
-0.3  
-40  
Max  
50  
Unit  
Vdc  
°C  
Input Voltage  
Operating Ambient Temperature  
(see Thermal Considerations section)  
Storage Temperature  
All  
TA  
85  
All  
All  
Tstg  
-55  
125  
°C  
I/O Isolation Voltage (100% factory tested)  
1500  
Vdc  
Electrical Specifications  
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature  
conditions.  
Parameter  
Device  
Symbol  
Min  
Typ  
Max  
Unit  
Operating Input Voltage  
Maximum Input Current  
(VIN=0V to 75V, IO=IO, max  
HC  
HC  
VIN  
18  
24  
36  
Vdc  
Adc  
IIN,max  
3.2  
)
Inrush Transient  
All  
All  
All  
I2t  
1
A2s  
mAp-p  
dB  
Input Reflected Ripple Current, peak-to-peak  
(5Hz to 20MHz, 12μH source impedance; VIN=0V to  
75V, IO= IOmax ; see Figure 9)  
3
Input Ripple Rejection (120Hz)  
50  
EMC, EN55022  
See EMC Considerations section  
CAUTION: This power module is not internally fused. An input line fuse must always be used.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an  
integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included,  
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies  
require a fast-acting fuse with a maximum rating of 5A (see Safety Considerations section). Based on the information  
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating  
can be used. Refer to the fuse manufacturer’s data sheet for further information.  