Data Sheet
HC006/010 Series DC-DC Power Module:
May 16, 2008
18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current
Test Configurations
Design Considerations
CURRENT PROBE
TO OSCILLOSCOPE
Input Source Impedance
LTEST
The power module should be connected to a low
ac-impedance source. A highly inductive source
Vin+
12μH
impedance can affect the stability of the power module.
For the test configuration in Figure 13, a 33μF
CS 220μF
E.S.R.<0.1Ω
33μF
electrolytic capacitor (ESR<0.7Ω at 100kHz), mounted
close to the power module helps ensure the stability of
the unit. Consult the factory for further application
guidelines.
@ 20°C 100kHz
Vin-
Safety Considerations
NOTE: Measure input reflected ripple current with a simulated
source inductance (LTEST) of 12μH. Capacitor CS offsets
possible battery impedance. Measure current as shown
above.
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standard,
i.e., UL 60950-1-3, CSA C22.2 No. 60950-00, and VDE
0805:2001-12 (IEC60950-1).
Figure 13. Input Reflected Ripple Current Test Setup.
C O PPER STRIP
VO(+)
VO(–)
RESISTIV E
LO AD
If the input source is non-SELV (ELV or a hazardous
voltage greater than 60 Vdc and less than or equal to
75Vdc), for the module’s output to be considered as
meeting the requirements for safety extra-low voltage
(SELV), all of the following must be true:
1uF
.
10uF
SC O PE
GROUND PLANE
The input source is to be provided with reinforced
insulation from any other hazardous voltages, including
the ac mains.
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
One VIN pin and one VOUT pin are to be grounded, or both
the input and output pins are to be kept floating.
Figure 14. Output Ripple and Noise Test Setup.
The input pins of the module are not operator accessible.
Another SELV reliability test is conducted on the whole
system (combination of supply source and subject
module), as required by the safety agencies, to verify that
under a single fault, hazardous voltages do not appear at
the module’s output.
Rdistribution Rcontact
Rcontact Rdistribution
Vin+
Vout+
RLOAD
VO
VIN
Note: Do not ground either of the input pins of the
module without grounding one of the output pins.
This may allow a non-SELV voltage to appear
between the output pins and ground.
Rdistribution Rcontact
Rcontact Rdistribution
Vin-
Vout-
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
For input voltages exceeding –60 Vdc but less than or
equal to –75 Vdc, these converters have been evaluated
to the applicable requirements of BASIC INSULATION
between secondary DC MAINS DISTRIBUTION input
(classified as TNV-2 in Europe) and unearthed SELV
outputs."All flammable materials used in the
Figure 15. Output Voltage and Efficiency Test Setup.
VO. IO
Efficiency
=
x
100 %
η
VIN. IIN
manufacturing of these modules are rated 94V-0 and
UL60950 A.2 for reduced thicknesses. The input to
these units is to be provided with a maximum 3A fast-
acting fuse in the unearthed lead."
LINEAGE POWER
8