Data Sheet  
HC006/010 Series DC-DC Power Module:  
May 16, 2008  
18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current  
begin to operate at an input voltage above the  
undervoltage lockout turn-on threshold.  
Feature Description  
Remote On/Off  
Over Voltage Protection  
Two remote on/off options are available. Positive logic  
turns the module on during a logic high voltage on the  
ON/OFF pin, and off during a logic low. Negative logic  
remote On/Off, device code suffix “1”, turns the module  
off during a logic high and on during a logic low.  
The output overvoltage protection clamp consists of  
control circuitry, independent of the primary regulation  
loop, that monitors the voltage on the output terminals.  
This control loop has a higher voltage set point than the  
primary loop (See the overvoltage clamp values in the  
Feature Specifications Table). In a fault condition, the  
overvoltage clamp ensures that the output voltage does  
not exceed Vo,ovsd, max. This provides a redundant  
voltage-control that reduces the risk of output  
overvoltage.  
VIN(+)  
VO  
Ion/off  
ON/OFF  
Over Temperature Protection  
To provide protection in a fault condition, the unit is  
equipped with a thermal shutdown circuit. The unit will  
shutdown if the overtemperature threshold of 125 oC is  
exceeded at the thermal reference point Tref . Once the  
unit goes into thermal shutdown it will then wait to cool  
before attempting to restart.  
Von/off  
COM  
VIN(-)  
Output Voltage Programming  
Figure 16. Remote On/Off Implementation.  
Trimming allows the output voltage set point to be  
increased or decreased, this is accomplished by  
connecting an external resistor between the TRIM pin  
and either the VO(+) pin or the VO(-) pin (COM pin) .  
To turn the power module on and off, the user must  
supply a switch (open collector or equivalent) to control  
the voltage (Von/off) between the ON/OFF terminal and  
the VIN(-) terminal. Logic low is –0.7V Von/off 1.2V.  
The maximum Ion/off during a logic low is 1mA, the switch  
should be maintain a logic low level whilst sinking this  
current.  
VIN(+)  
VO(+)  
VOTRIM  
COM  
Rtrim-up  
ON/OFF  
During a logic high, the maximum Von/off generated by  
the module is 15V, and the maximum allowable leakage  
current at Von/off = 15V is 50μA.  
LOAD  
Rtrim-down  
If not using the remote on/off feature:  
For positive logic, leave the ON/OFF pin open.  
For negative logic, short the ON/OFF pin to VIN(-).  
Overcurrent Protection  
VIN(-)  
To provide protection in a fault (output overload) condi-  
tion, the module is equipped with internal current-limiting  
circuitry, and can endure current limiting continuously.  
At the instance of current-limit inception, the output  
current begins to tail-out. When an overcurrent condition  
exists beyond a few seconds, the module enters a  
“hiccup” mode of operation, whereby it shuts down and  
automatically attempts to restart upon cooling. While the  
fault condition exists, the module will remain in this  
hiccup mode, and can remain in this mode until the fault  
is cleared. The unit operates normally once the output  
current is reduced back into its specified range.  
Figure 17. Circuit Configuration to Trim Output  
Voltage.  
Connecting an external resistor (Rtrim-down) between the  
TRIM pin and the COM pin decreases the output voltage  
set point. The following equation determines the value  
of trim-down resistor needed to decrease the output  
voltage from Vo,set to Vo:  
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout  
limit, the module operation is disabled. The module will  
LINEAGE POWER  
9