Data Sheet  
Austin MiniLynxTM 12V SIP Non-isolated Power Modules:  
March 31, 2008  
8.3 – 14Vdc Input; 0.75Vdc to 5.5Vdc Output; 3A output current  
Feature Description  
VIN+  
MODULE  
R
Remote On/Off  
pull-up  
Austin MiniLynxTM 12V SIP power modules feature an  
On/Off pin for remote On/Off operation. Two On/Off  
logic options are available in the Austin MiniLynxTM  
12V series modules. Positive Logic On/Off signal,  
device code suffix “4”, turns the module ON during a  
logic High on the On/Off pin and turns the module  
OFF during a logic Low. Negative logic On/Off signal,  
no device code suffix, turns the module OFF during  
logic High and turns the module ON during logic Low.  
I
ON/OFF  
ON/OFF  
+
PWM Enable  
V
ON/OFF  
R1  
R2  
Q2  
CSS  
Q1  
GND  
_
For positive logic modules, the circuit configuration for  
using the On/Off pin is shown in Figure 27. The  
On/Off pin is an open collector/drain logic input signal  
(Von/Off) that is referenced to ground. During a logic-  
high (On/Off pin is pulled high internal to the module)  
when the transistor Q1 is in the Off state, the power  
module is ON. Maximum allowable leakage current of  
the transistor when Von/off = VIN,max is 10µA.  
Applying a logic-low when the transistor Q1 is turned-  
On, the power module is OFF. During this state  
VOn/Off must be less than 0.3V. When not using  
positive logic On/off pin, leave the pin unconnected or  
tie to VIN.  
Figure 28. Circuit configuration for using  
negative logic On/OFF.  
Overcurrent Protection  
To provide protection in a fault (output overload)  
condition, the unit is equipped with internal  
current-limiting circuitry and can endure current  
limiting continuously. At the point of current-limit  
inception, the unit enters hiccup mode. The unit  
operates normally once the output current is brought  
back into its specified range. The typical average  
output current during hiccup is 3.5A.  
VIN+  
MODULE  
R2  
Input Undervoltage Lockout  
At input voltages below the input undervoltage lockout  
limit, module operation is disabled. The module will  
begin to operate at an input voltage above the  
undervoltage lockout turn-on threshold.  
ON/OFF  
Q2  
+
R1  
V
ON/OFF  
I
ON/OFF  
PWM Enable  
R3  
R4  
Overtemperature Protection  
Q1  
To provide over temperature protection in a fault  
condition, the unit relies upon the thermal protection  
feature of the controller IC. The unit will shutdown if  
the thermal reference point Tref2, (see Figure 31)  
exceeds 140oC (typical), but the thermal shutdown is  
not intended as a guarantee that the unit will survive  
temperatures beyond its rating. The module will  
automatically restarts after it cools down.  
Q3  
CSS  
GND  
_
Figure 27. Circuit configuration for using positive  
logic On/OFF.  
For negative logic On/Off devices, the circuit  
configuration is shown is Figure 28. The On/Off pin is  
pulled high with an external pull-up resistor (typical  
Rpull-up = 68k, +/- 5%). When transistor Q1 is in the  
Off state, logic High is applied to the On/Off pin and  
the power module is Off. The minimum On/off voltage  
for logic High on the On/Off pin is 2.5 Vdc. To turn  
the module ON, logic Low is applied to the On/Off pin  
by turning ON Q1. When not using the negative logic  
On/Off, leave the pin unconnected or tie to GND.  
LINEAGE POWER  
12