欢迎访问ic37.com |
会员登录 免费注册
发布采购

PALCE22V10H-10PC/5 参数 Datasheet PDF下载

PALCE22V10H-10PC/5图片预览
型号: PALCE22V10H-10PC/5
PDF下载: 下载PDF文件 查看货源
内容描述: 24引脚EE CMOS (零功耗)多功能PAL器件 [24-Pin EE CMOS (Zero Power) Versatile PAL Device]
分类和应用: 可编程逻辑器件光电二极管输入元件时钟
文件页数/大小: 34 页 / 662 K
品牌: LATTICE [ LATTICE SEMICONDUCTOR ]
 浏览型号PALCE22V10H-10PC/5的Datasheet PDF文件第5页浏览型号PALCE22V10H-10PC/5的Datasheet PDF文件第6页浏览型号PALCE22V10H-10PC/5的Datasheet PDF文件第7页浏览型号PALCE22V10H-10PC/5的Datasheet PDF文件第8页浏览型号PALCE22V10H-10PC/5的Datasheet PDF文件第10页浏览型号PALCE22V10H-10PC/5的Datasheet PDF文件第11页浏览型号PALCE22V10H-10PC/5的Datasheet PDF文件第12页浏览型号PALCE22V10H-10PC/5的Datasheet PDF文件第13页  
CAPACITANCE 1  
Parameter  
Symbol  
Parameter Description  
Input Capacitance  
Output Capacitance  
Test Conditions  
Typ  
Unit  
C
V = 2.0 V  
IN  
V = 5.0 V  
5
IN  
CC  
T = 25°C  
pF  
A
C
V
= 2.0 V  
8
OUT  
OUT  
f = 1 MHz  
Note:  
1. These parameters are not 100% tested, but are evaluated at initial characterization and at any time the design is modified where  
capacitance may be affected.  
SWITCHING CHARACTERISTICS OVER COMMERCIAL OPERATING RANGES 1  
-5  
Parameter  
Symbol  
Parameter Description  
Input or Feedback to Combinatorial Output  
Min  
Max  
Unit  
ns  
t
5
PD  
t
Setup Time from Input or Feedback  
Setup Time from SP to Clock  
Hold Time  
3
4
0
ns  
S1  
t
ns  
S2  
t
ns  
H
t
Clock to Output  
4
ns  
CO  
t
Skew Between Registered Outputs (Note 2)  
Asynchronous Reset to Registered Output  
Asynchronous Reset Width  
0.5  
7.5  
ns  
SKEWR  
t
ns  
AR  
t
4.5  
4.5  
ns  
ARW  
t
Asynchronous Reset Recovery Time  
Synchronous Preset Recovery Time  
ns  
ARR  
t
4.5  
ns  
SPR  
t
LOW  
2.5  
ns  
WL  
Clock Width  
HIGH  
t
2.5  
ns  
WH  
External Feedback  
Maximum Frequency (Note 3) Internal Feedback (f  
1/(t + t  
)
142.8  
150  
200  
MHz  
MHz  
MHz  
ns  
S
CO  
f
)
1/(t + t ) (Note 4)  
CF  
MAX  
CNT  
S
No Feedback  
Input to Output Enable Using Product Term Control  
Input to Output Disable Using Product Term Control  
1/(t + t )  
WH WL  
t
6
EA  
t
5.5  
ns  
ER  
Notes:  
1. See “Switching Test Circuit” for test conditions.  
2. Skew is measured with all outputs switching in the same direction.  
3. These parameters are not 100% tested, but are calculated at initial characterization and at any time the design is modified where  
frequency may be affected.  
4. t is a calculated value and is not guaranteed. t can be found using the following equation:  
CF  
CF  
t
= 1/f  
(internal feedback) - t .  
CF  
MAX S  
PALCE22V10H-5 (Coml)  
9
 复制成功!