CAPACITANCE 1
Parameter
Symbol
Parameter Description
Test Conditions
Typ
Unit
C
Input Capacitance
Output Capacitance
V = 2.0 V
IN
V = 5.0 V
CC
5
IN
T = 25°C
pF
A
C
V
= 2.0 V
8
OUT
OUT
f = 1 MHz
Note:
1. These parameters are not 100% tested, but are evaluated at initial characterization and at any time the design is modified where
capacitance may be affected.
SWITCHING CHARACTERISTICS OVER COMMERCIAL OPERATING RANGES 1
-15
-25
Parameter
Symbol
Parameter Description
Input or Feedback to Combinatorial Output
Min
Max
Min
Max
Unit
ns
t
15
25
PD
t
Setup Time from Input, Feedback or SP to Clock
Hold Time
10
0
15
0
ns
S
t
ns
H
t
Clock to Output
10
20
15
25
ns
CO
t
Asynchronous Reset to Registered Output
Asynchronous Reset Width
ns
AR
t
15
10
10
8
25
25
ns
ARW
t
Asynchronous Reset Recovery Time
Synchronous Preset Recovery Time
ns
ARR
t
25
ns
SPR
t
LOW
Clock Width
13
ns
WL
t
HIGH
8
13
ns
WH
External Feedback
1/(t + t
)
50
58.8
33.3
35.7
MHz
MHz
ns
Maximum Frequency
(Note 2)
S
CO
f
MAX
Internal Feedback (f
)
1/(t + t ) (Note 3)
CF
CNT
S
t
Input to Output Enable Using Product Term Control
Input to Output Disable Using Product Term Control
15
15
25
25
EA
t
ns
ER
Notes:
1. See “Switching Test Circuit” for test conditions.
2. These parameters are not 100% tested, but are evaluated at initial characterization and at any time
the design is modified where frequency may be affected.
3. t is a calculated value and is not guaranteed. t can be found using the following equation:
CF
CF
t
= 1/f
(internal feedback) - t .
CF
MAX S
PALCE22V10H-15/25, Q-15/25 (Com’l)
17