42 | Keysight | FieldFox Handheld Analyzers 4/6.5/9/14/18/26.5/32/44/50 GHz - Data Sheet  
USB Power Sensor Measurements versus Frequency (continued)  
Source frequency span must be equal to receiver frequency span.  
Receiver sweep direction: forward (default setting) or reverse.  
For some DUTs, the output frequency may sweep in a reverse direction, as compared to the source frequency. The basic relationships  
between the source, receiver and offset frequencies are shown in the table below. The FieldFox analyzer includes an offset calculator  
that ensures a fast measurement setup.  
Src sweep direction  
Forward f2src > f1src  
Forward f2src > f1src  
Rx sweep direction  
Forward f2rx > f1rx  
Reverse f2rx > f1rx  
Frequency calculations  
Receiver frequency = Source frequency ± Offset  
Receiver frequency = Offset — Source Frequency Offset > Source frequency  
See FieldFox Configuration Guide for option information. Many capabilities listed in this Data Sheet require options.  
Description  
Measurements  
Source power, gain/loss and receiver (Rx) power  
Gain = Rx power / source power (memory). Source power (memory) is measured during setup.  
Refer to the test port output power typical data on page 5.  
Output power  
Dynamic range  
The dynamic range with FOPS is dependent on FieldFox’s output power and the power sensor’s dynamic range.  
Supported USB power sensors: www.keysight.com/find/fieldfoxsupport  
The graph below shows a filter measurement using two different power sensors, the U2002A (—60 to +20 dBm) and the U2021XA  
(—45 to +20 dBm). While a filter is not commonly measured using FOPS, it is a useful device for demonstrating dynamic range.  
For both measurements, the FieldFox source power was set to —1 dBm, the maximum available in the selected frequency range of  
7.25 to 13.25 GHz. An external amplifier was not used in this case, but one can be added to increase the source power and hence  
dynamic range.  
Example showing typical dynamic range of FOPS  