欢迎访问ic37.com |
会员登录 免费注册
发布采购

N9913A-211 参数 Datasheet PDF下载

N9913A-211图片预览
型号: N9913A-211
PDF下载: 下载PDF文件 查看货源
内容描述: [FieldFox Handheld Analyzers]
分类和应用:
文件页数/大小: 48 页 / 6709 K
品牌: KEYSIGHT [ Keysight Technologies ]
 浏览型号N9913A-211的Datasheet PDF文件第37页浏览型号N9913A-211的Datasheet PDF文件第38页浏览型号N9913A-211的Datasheet PDF文件第39页浏览型号N9913A-211的Datasheet PDF文件第40页浏览型号N9913A-211的Datasheet PDF文件第42页浏览型号N9913A-211的Datasheet PDF文件第43页浏览型号N9913A-211的Datasheet PDF文件第44页浏览型号N9913A-211的Datasheet PDF文件第45页  
41 | Keysight | FieldFox Handheld Analyzers 4/6.5/9/14/18/26.5/32/44/50 GHz - Data Sheet  
External USB Power Sensor Support  
The external USB power sensor option supports various Keysight USB power sensors. For an up-to-date listing of the supported power  
sensors, visit http://www.keysight.com/find/fieldfoxsupport.  
Description  
Setup parameters  
Functions  
Frequency  
Relative/absolute measurements, offsets, units of dBm or watts, or dB or %, minimum and maximum limits.  
Internal source  
FieldFox’s internal source can be turned on in the USB power sensor mode. CW frequency and nominal power  
level control are available.  
Pulse Measurements  
FieldFox’s pulse measurement option can be used to characterize RF pulses such as those used in radar and electronic warfare  
systems. Measurements are made using FieldFox and Keysight’s USB peak power sensors.  
Performance specifications such as frequency, dynamic range and minimum pulse width depend on the peak power sensor. Supported  
peak power sensors: http://www.keysight.com/find/fieldfoxsupport  
Description  
Setup parameters  
Functions  
Frequency, time (center), time/division, gating, triggering, video bandwidth, averaging  
Average power, peak power, and peak to average ratio  
Analog gauge display and digital display, dBm and watts  
Relative/absolute measurements, offset, dB or %, minimum and maximum limits  
Trace graph for pulse profiling with gating  
Rise time, fall time, pulse width, pulse period, pulse repetition frequency  
USB Power Sensor Measurements versus Frequency  
This feature allows FieldFox’s source frequency to be set independently from the power sensor (receiver) frequency. With frequen-  
cy-offset using power sensor (FOPS), the frequency of both the source and receiver are swept, and the two track each other. The offset  
frequency can be negative, zero, or positive.  
FOPS can be used to characterize the scalar transmission response of devices such as mixers and converters. This frequency-offset  
capability is necessary for conversion loss/gain measurements on frequency-translating devices, since by definition, the input and  
output frequencies of the DUT are different. The FieldFox source stimulates the DUT and the power sensor is used as the measurement  
receiver.  
Since power sensors are inherently broadband devices (not frequency-selective), the user should ensure that only the signal of interest  
is present at the power sensor input and that all others signals are filtered appropriately.  
Setup parameters  
Source frequency  
Receiver frequency  
Frequency offset  
Frequency step size  
Number of points  
Center/span or start/stop  
Range determined by power sensor range  
Positive offset or negative offset  
30 kHz minimum  
2 to 1601  
Combination of number of points and frequency step size limited by span.  
Dwell time/point 0 to 1.0 sec  
 复制成功!