24 | Keysight | Infiniium 90000 Series Oscilloscopes - Data Sheet
Infiniium 90000A Series Oscilloscopes
Performance characteristics
Vertical
Input channels
Analog bandwidth (–3 dB) 1, 5
Four
90254A
2.5 GHz
90404A
90604A
90804A
91204A
91304A
4 GHz
6 GHz
8 GHz
12 GHz
12 GHz
DSP enhanced bandwidth 4
Rise time/fall time 6
10 to 90%
20 to 80%
Input impedance 7
Sensitivity 2
91304A: 13-GHz real-time, user-selectable DSP enhanced bandwidth
90254A
140 ps
105 ps
50 Ω, ± 3%
1 mV/div to 1 V/div
DC
90404A
105 ps
79 ps
90604A
70 ps
53 ps
90804A
54 ps
38 ps
91204A
35 ps
25 ps
91304A
32 ps
23 ps
Input coupling
Vertical resolution 3
8 bits, ≥ 12 bits with averaging
Channel to channel isolation (any two
channels with equal V/div settings
DC to 3 GHz: 90804A/91204A/91304A: 60 dB (≥ 1000:1)
90254A/90404A/90604A: 50 dB (≥ 316:1)
3 to 8 GHz: 40 dB (≥ 100:1)
8 GHz to BW: 35 dB (≥ 56:1)
± 2% of full scale at full resolution channel scale (± 2.5% for 5mV/div)
± 5 V
DC gain accuracy 1, 2
Maximum input voltage 1
Offset range
Vertical sensitivity
Available offset
± 0.4 V
± 0.9 V
± 1.6 V
± 3.0 V
0 mV/div to ≥ 40 mV/div
> 40 mV/div to ≥ 75 mV/div
> 75 mV/div to ≥ 130 mV/div
> 130 mV/div to ≥ 240 mV/div
> 240 mV/div
≤ 3.5 V: ± (2% of channel offset + 1% of full scale) + 1 mV
> 3.5 V: ± (2% of channel offset + 1% of full scale)
± 4 div from center screen
± 4.0 V
Offset accuracy 1, 2
Dynamic range
DC voltage measurement accuracy 1, 2
Dual cursor: ± [(DC gain accuracy) + (resolution)]
Single cursor: ± [(DC gain accuracy) + (offset accuracy) + (resolution/2)]
RMS noise floor (scope only)
Volts/div
5 mV
90254A
153 μV
90404A
199 μV
90604A
259 μV
295 μV
424 μV
985 μV
1.92 mV
3.71 mV
9.91 mV
19.2 mV
90804A
322 μV
358 μV
498 μV
1.15 mV
2.22 mV
4.28 mV
11.5 mV
22.3 mV
91204A
435 μV
483 μV
650 μV
1.45 mV
2.80 mV
5.41 mV
14.7 mV
28.5 mV
91304A
467 μV
536 μV
758 μV
1.73 mV
3.37 mV
6.58 mV
17.4 mV
34.1 mV
10 mV
20 mV
50 mV
100 mV
200 mV
500 mV
1 V
183 μV
275 μV
645 μV
1.27 mV
2.47 mV
6.48 mV
12.5 mV
232 μV
342 μV
799 μV
1.56 mV
3.03 mV
8.00 mV
15.6 mV
1. Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period, and ± 5 °C from annual calibration
temperature�
2. Full scale is defined as 8 vertical divisions. Magnification is used below 5 mV/div. Below 5 mV/div, full-scale is defined as 40 mV. The major scale settings are
5 mV, 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1 V�
3� Vertical resolution for 8 bits = 0�4% of full scale, for 12 bits = 0�024% of full scale�
4� 13 GHz DSP enhanced bandwidth not applicable at 5 mV/div�
5. FFT amplitude readings are affected by scope and probe bandwidth limitations and input amplifiers roll-off (e.g. 3 dB roll-off at specified bandwidth of
scope/probe)�
6� The FFT signal to noise ratio varies with volts/division setting, memory depth and use of time or frequency averaging�
7a. Noise is the displayed noise floor. SlewRate is the displayed slew rate of the signal at the threshold crossings. Sample rate = max, sin(x)/x interpolation
enabled�
7b. Measurement threshold = fixed voltage at 50% level.
7c. Time ranges ≤ 10 μs.
8� Values represent time error between two edges on a single channel� Standard deviation value refers to the standard deviation of 256 consecutive
measurements performed using an individual instrument. Reading is the displayed DTMA measurement value. TimeScaleAccy is the oscilloscope’s specified
time scale accuracy�
9. Internal edge trigger mode. Trigger threshold = fixed voltage at 50% level. The slew rate independent value in the formula represents the traditional trigger
jitter�
10. Requires Option 010 user defined function.
11� 11�8 GHz analog bandwidth at 5 mV/div for DSO91304A and DSO91204A models�
12� Typically triggers as low as 5 mV/div sensitivity�