IRU3007
TYPICAL APPLICATION
(Dual Layout with HIP6019)
R22
12V
5V
L1
C5
R9
C8
R12
C10
C14
C2
C3
OCSet2
UGate2
V12 OCSet1
UGate1
R10
R13
Q3
Q4
Q1
L3
L2
VOUT2
3.0V - 3.5V
Phase2
Phase1
LGate1
VOUT1
1.8V - 3.5V
C16
C1
R14
C4
R1
C13
R15
D1
R16
R21
PGnd
VSEN1
VSEN2
Fb2
U1
Fb1
R2
R17
IRU3007
C15
R19
R11
C12
V5/Comp2
NC/Comp1
C6
R3
C11
R18
C19
R4
R5
C7
PGood
Fault/Rt
VID0
PGood
Q2
Gate3
Fb3
VOUT3
1.5V
C17
C18
R6
VID1
VID2
VOUT4
2.5V
VOUT4
Fb4
VID3
R7
R8
VID4
Gnd
SS
5V
C20
C9
Figure 4 - Typical application of IRU3007 in a dual layout with HIP6019 for an on-board DC-DC converter
providing power for the Vcore, GTL+, Clock supply as well as an on-board 3.3V I/O supply for the
Deschutes and the next generation processor application.
Components that need to be modified to make the dual layout work for HIP6019 and IRU3007:
Part #
HIP6019
IRU3007
R4
V
O
R11
O
S
R18
V
O
C6
V
O
C7
V
O
C9
O
V
C11
V
O
C12
V
O
C19
O
V
C20
V
O
S - Short
O - Open
V - See IR or Harris parts list for the value
Table 2 - Dual layout component table.
Rev. 2.1
08/20/02
www.irf.com
9