HIGH TEMPERATURE REVERSE BIAS (HTRB)
T0220 Package
Junction Temperature:
Applied Bias:
Tj = as specified below
Vge = 0V
Vce = 80% of maximum rated BVces
N Channel
DEVICE
TYPE
LOW FREQUENCY ( Standard )
EQUIVALENT FAILURE RATE @
FAILURES
DEV-HRS 90°C & 60% UCL
DATE
TEMP VOLTAGE QTY ACTUAL
CODE
MAX
TEST
@ 90°C
TIME #
MODE
FITs
(deg C)
(V)
(hours)
(note b)
(note a)
9544
150
600
20
2008 0
3.73E+06
245
9606
150
600
20
2008 0
3.73E+06
245
TOTALS
40
4016 0
7.47E+06
123
IRGBC20S
IRGBC40S
N Channel
DEVICE
TYPE
DATE
CODE
TEMP VOLTAGE QTY
MAX
(V)
600
600
900
MID FREQUENCY ( Fast )
ACTUAL
TEST
TIME
(hours)
20
2008
20
2007
20
2008
EQUIVALENT FAILURE RATE @
FAILURES
DEV-HRS 90°C & 60% UCL
@ 90°C
MODE
FITs
(note b)
(note a)
3.73E+06
245
3.73E+06
245
3.73E+06
245
1.12E+07
82
#
0
0
0
IRGBC30F
IRGNC30FD2
IRGBF30F
(deg C)
9537
150
9640
150
9613
150
TOTALS
60
6023 0
NOTES
a.
b.
One FIT represents one failure in one billion (1.0E+09) hours.
FAILURE MODES:
IGBT / CoPack
Quarterly Reliability Report
Page 10 of 35