内容描述: 双路, 128抽头,低电压数字控制电位器( XDCP ? ) [Dual, 128-Tap, Low Voltage Digitally Controlled Potentiometer (XDCP?)]
分类和应用: 电位器
文件页数/大小: 21 页 / 637 K
品牌: INTERSIL [ Intersil ]
 浏览型号23425WFVZ-TK的Datasheet PDF文件第11页浏览型号23425WFVZ-TK的Datasheet PDF文件第12页浏览型号23425WFVZ-TK的Datasheet PDF文件第13页浏览型号23425WFVZ-TK的Datasheet PDF文件第14页浏览型号23425WFVZ-TK的Datasheet PDF文件第16页浏览型号23425WFVZ-TK的Datasheet PDF文件第17页浏览型号23425WFVZ-TK的Datasheet PDF文件第18页浏览型号23425WFVZ-TK的Datasheet PDF文件第19页  
ISL23428  
When the device enters shutdown, all current DCP WR settings are  
SPI Serial Interface  
maintained. When the device exits shutdown, the wipers will  
return to the previous WR settings after a short settling time  
(see Figure 26).  
The ISL23428 supports an SPI serial protocol, mode 0. The  
device is accessed via the SDI input and SDO output with data  
clocked in on the rising edge of SCK, and clocked out on the  
falling edge of SCK. CS must be LOW during communication with  
the ISL23428. The SCK and CS lines are controlled by the host or  
master. The ISL23428 operates only as a slave device.  
All communication over the SPI interface is conducted by  
sending the MSB of each byte of data first.  
POWER-UP  
MID SCALE = 40H  
USER PROGRAMMED  
AFTER SHDN  
Protocol Conventions  
The SPI protocol contains Instruction Byte followed by one or more  
Data Bytes. A valid Instruction Byte contains instruction as the three  
MSBs, with the following five register address bits (see Table 3).  
SHDN RELEASED  
SHDN ACTIVATED  
WIPER RESTORE TO  
THE ORIGINAL POSITION  
SHDN MODE  
TIME (s)  
The next byte sent to the ISL23428 is the Data Byte.  
TABLE 3. INSTRUCTION BYTE FORMAT  
0
FIGURE 26. SHUTDOWN MODE WIPER RESPONSE  
BIT #  
7
6
5
4
3
2
1
0
I2  
I1  
I0  
R4  
R3  
R2  
R1  
R0  
Table 4 contains a valid instruction set for ISL23428.  
If the [R4:R0] bits are zero or one, then the read or write is to the  
WRi register. If the [R4:R0] are 10000, then the operation is to  
the ACR.  
TABLE 4. INSTRUCTION SET  
INSTRUCTION SET  
I2  
0
0
0
1
1
I1  
0
0
1
0
1
I0  
0
1
1
0
0
R4  
X
R3  
X
R2  
X
R1  
X
R0  
X
OPERATION  
NOP  
X
X
X
X
X
ACR READ  
X
X
X
X
X
ACR WRTE  
R4  
R4  
R3  
R3  
R2  
R2  
R1  
R1  
R0  
R0  
WRi or ACR READ  
WRi or ACR WRTE  
Where X means “do not care”.  