FULL SCALE PRESSURE
kPa
bar
mbar
PSI
atm
mm Hg
m H2O
Inches H2O
40
0.4
400
5.8
0.4
300
4.1
161
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Conditions
Min
Max
Unit
Supply voltage
VS+
TS
Ta = 25 oC
20
+150
20
V
oC
Storage temperature
Pressure overload
-40
Bar
ELECTRICAL CHARACTERISTICS
(Reference conditions: Supply Voltage VS+ = 5 Vdc; Ambient Temperature Ta = 25°C )
Parameter
Min
0
Typ
Max
0.4
125
3.8
27
Unit
Notes
Operating Pressure Range
Operating Temperature Range
Bridge Resistance
Full-scale span (FS)
Zero Pressure Offset
Linearity
Bar
°C
-40
3.0
18
3.4
22.5
0
kΩ
mV
mV
-40
40
0.15
0.2
% FS
1
2
Temperature Coefficient of Resistance
Span
Offset
+ 2400
- 1500
- 80
+ 2800
- 1900
+ 3300
- 2300
+ 80
ppm/°C
ppm/°C
µV/°C
Pressure Hysteresis
Repeatability
0.05
0.05
0.15
0.15
0.3
% FS
% FS
% FS
3
4
5
Temperature Hysteresis
NOTES
1) Deviation at one half full-scale pressure from the least squares best line fit over pressure range (0 to 0.4 bar).
2) Slope of the endpoint straight line from 25°C to 60°C.
3) Output deviation at any pressure within the specified range, when this pressure is cycled to and from the
minimum or maximum rated pressure, at 25°C.
4) Same as 3) after 10 pressure cycles
5) Maximum difference in offset after one thermal cycle from -40°C to +125°C.
DA763_002.doc
00007631360
ECN 1147
October 9, 2008
3/4