8086  
MASKABLE INTERRUPT (INTR)  
HALT  
The 8086 provides a single interrupt request input  
(INTR) which can be masked internally by software  
with the resetting of the interrupt enable FLAG  
status bit. The interrupt request signal is level trig-  
gered. It is internally synchronized during each clock  
cycle on the high-going edge of CLK. To be re-  
sponded to, INTR must be present (HIGH) during  
the clock period preceding the end of the current  
instruction or the end of a whole move for a block-  
type instruction. During the interrupt response se-  
quence further interrupts are disabled. The enable  
bit is reset as part of the response to any interrupt  
(INTR, NMI, software interrupt or single-step), al-  
though the FLAGS register which is automatically  
pushed onto the stack reflects the state of the proc-  
essor prior to the interrupt. Until the old FLAGS reg-  
ister is restored the enable bit will be zero unless  
specifically set by an instruction.  
When a software ‘‘HALT’’ instruction is executed the  
processor indicates that it is entering the ‘‘HALT’’  
state in one of two ways depending upon which  
mode is strapped. In minimum mode, the processor  
issues one ALE with no qualifying bus control sig-  
nals. In maximum mode, the processor issues ap-  
propriate HALT status on S , S , and S ; and the  
0
2
1
8288 bus controller issues one ALE. The 8086 will  
not leave the ‘‘HALT’’ state when a local bus ‘‘hold’’  
is entered while in ‘‘HALT’’. In this case, the proces-  
sor reissues the HALT indicator. An interrupt request  
or RESET will force the 8086 out of the ‘‘HALT’’  
state.  
READ/MODIFY/WRITE (SEMAPHORE)  
OPERATIONS VIA LOCK  
The LOCK status information is provided by the  
processor when directly consecutive bus cycles are  
required during the execution of an instruc-  
tion. This provides the processor with the capability  
of performing read/modify/write operations on  
memory (via the Exchange Register With Memory  
instruction, for example) without the possibility of an-  
other system bus master receiving intervening mem-  
ory cycles. This is useful in multi-processor system  
configurations to accomplish ‘‘test and set lock’’ op-  
erations. The LOCK signal is activated (forced LOW)  
in the clock cycle following the one in which the soft-  
ware ‘‘LOCK’’ prefix instruction is decoded by the  
EU. It is deactivated at the end of the last bus cycle  
of the instruction following the ‘‘LOCK’’ prefix in-  
struction. While LOCK is active a request on a RQ/  
GT pin will be recorded and then honored at the end  
of the LOCK.  
During the response sequence (Figure 6) the proc-  
essor executes two successive (back-to-back) inter-  
rupt acknowledge cycles. The 8086 emits the LOCK  
signal from T of the first bus cycle until T of the  
2
2
second. A local bus ‘‘hold’’ request will not be hon-  
ored until the end of the second bus cycle. In the  
second bus cycle a byte is fetched from the external  
interrupt system (e.g., 8259A PIC) which identifies  
the source (type) of the interrupt. This byte is multi-  
plied by four and used as a pointer into the interrupt  
vector lookup table. An INTR signal left HIGH will be  
continually responded to within the limitations of the  
enable bit and sample period. The INTERRUPT RE-  
TURN instruction includes a FLAGS pop which re-  
turns the status of the original interrupt enable bit  
when it restores the FLAGS.  
231455–9  
Figure 6. Interrupt Acknowledge Sequence  