欢迎访问ic37.com |
会员登录 免费注册
发布采购

631XESB 参数 Datasheet PDF下载

631XESB图片预览
型号: 631XESB
PDF下载: 下载PDF文件 查看货源
内容描述: [Multifunction Peripheral, CMOS, PBGA641, 40 X 40 MM, MICRO, BGA-641]
分类和应用:
文件页数/大小: 106 页 / 3572 K
品牌: INTEL [ INTEL ]
 浏览型号631XESB的Datasheet PDF文件第98页浏览型号631XESB的Datasheet PDF文件第99页浏览型号631XESB的Datasheet PDF文件第100页浏览型号631XESB的Datasheet PDF文件第101页浏览型号631XESB的Datasheet PDF文件第102页浏览型号631XESB的Datasheet PDF文件第103页浏览型号631XESB的Datasheet PDF文件第104页浏览型号631XESB的Datasheet PDF文件第106页  
Debug Tools Specifications  
9
Debug Tools Specifications  
9.1  
Logic Analyzer Interface (LAI)  
Intel is working with two logic analyzer vendors to provide logic analyzer interfaces  
(LAIs) for use in debugging Pentium 4 processor systems. Tektronix and Agilent should  
be contacted to get specific information about their logic analyzer interfaces. The  
following information is general in nature. Specific information must be obtained from  
the logic analyzer vendor.  
Due to the complexity of Pentium 4 processor systems, the LAI is critical in providing  
the ability to probe and capture FSB signals. There are two sets of considerations to  
keep in mind when designing a Pentium 4 processor system that can make use of an  
LAI: mechanical and electrical.  
9.1.1  
Mechanical Considerations  
The LAI is installed between the processor socket and the processor. The LAI lands plug  
into the processor socket, while the processor lands plug into a socket on the LAI.  
Cabling that is part of the LAI egresses the system to allow an electrical connection  
between the processor and a logic analyzer. The maximum volume occupied by the LAI,  
known as the keepout volume, as well as the cable egress restrictions, should be  
obtained from the logic analyzer vendor. System designers must make sure that the  
keepout volume remains unobstructed inside the system. Note that it is possible that  
the keepout volume reserved for the LAI may differ from the space normally occupied  
by the processor heatsink. If this is the case, the logic analyzer vendor will provide a  
cooling solution as part of the LAI.  
9.1.2  
Electrical Considerations  
The LAI will also affect the electrical performance of the FSB; therefore, it is critical to  
obtain electrical load models from each of the logic analyzers to be able to run system  
level simulations to prove that their tool will work in the system. Contact the logic  
analyzer vendor for electrical specifications and load models for the LAI solution it  
provides.  
§ §  
Datasheet  
105