Electrical Characteristics
Table 5
lists the maximum allowed input overshoot voltage and the duration of the
overshoot voltage as a percentage of device lifetime. The maximum allowed
overshoot duration is specified as a percentage of high time over the lifetime of the
device. A DC signal is equivalent to 100% of the duty cycle. For example, a signal that
overshoots to 3.95 V can be at 3.95 V for only ~21% over the lifetime of the device; for
a device lifetime of 10 years, the overshoot duration amounts to ~2 years.
Table 5. Maximum Allowed Overshoot During Transitions
Symbol
Description
Condition (V)
3.8
3.85
3.9
3.95
Vi (AC)
AC input voltage
4
4.05
4.1
4.15
4.2
Overshoot Duration as %
@ T
J
= 100°C
100
64
36
21
12
7
4
2
1
Unit
%
%
%
%
%
%
%
%
%
Stratix V Device Datasheet
December 2015