CV-51002
2015.12.04
5
Recommended Operating Conditions
Recommended Operating Conditions
Table 3: Recommended Operating Conditions for Cyclone V Devices
This table lists the steady-state voltage values expected from Cyclone V devices. Power supply ramps must all be strictly monotonic, without plateaus.
Symbol
Description
Condition
Minimum(2)
Typical
Maximum(2)
Unit
Devices without
internal scrubbing
feature
1.07
1.1
1.13
V
Core voltage, periphery circuitry power
supply, transceiver physical coding
sublayer (PCS) power supply, and
transceiver PCI Express® (PCIe®) hard IP
digital power supply
VCC
Devices with internal
scrubbing feature (with
SC suffix) (3)
1.12
1.15
1.18
V
VCC_AUX
Auxiliary supply
—
2.375
3.135
2.85
2.5
3.3
3.0
2.5
2.625
3.465
3.15
V
V
V
V
3.3 V
3.0 V
2.5 V
(4)
VCCPD
I/O pre-driver power supply
2.375
2.625
(2)
(3)
(4)
The power supply value describes the budget for the DC (static) power supply tolerance and does not include the dynamic tolerance requirements.
Refer to the PDN tool for the additional budget for the dynamic tolerance requirements.
The SEU internal scrubbing feature is available for Cyclone V E, GX, SE, and SX devices with the "SC" suffix in the part number. For device
availability and ordering, contact your local Altera sales representatives.
VCCPD must be 2.5 V when VCCIO is 2.5, 1.8, 1.5, 1.35, 1.25, or 1.2 V. VCCPD must be 3.0 V when VCCIO is 3.0 V. VCCPD must be 3.3 V when VCCIO is
3.3 V.
Cyclone V Device Datasheet
Send Feedback
Altera Corporation