Electrical Characteristics
Page 9
OCT Specifications
If you enable on-chip termination (OCT) calibration, calibration is automatically
performed at power up for I/Os connected to the calibration block.
lists the Arria V OCT termination calibration accuracy specifications. The OCT
calibration accuracy is valid at the time of calibration only.
Table 8. OCT Calibration Accuracy Specifications for Arria V Devices
Calibration Accuracy
Symbol
Description
Internal series termination
with calibration
(25-Ω setting)
Internal series termination
with calibration
(50-Ω setting)
Internal series termination
with calibration
(34-Ω and 40-Ω setting)
Internal series termination
with calibration
(48-Ω, 60-Ω, and 80-Ω
setting)
Internal parallel
termination with
calibration (50-Ω setting)
Internal parallel
termination with
calibration
(20-Ω, 30-Ω, 40-Ω,
60-Ω, and 120-Ω setting)
Internal parallel
termination with
calibration
(60-Ω and 120-Ω setting)
Internal left shift series
termination with
calibration
(25-Ω R
S_left_shift
setting)
Conditions (V)
I3, C4
25-Ω R
S
V
CCIO
= 3.0, 2.5, 1.8,
1.5, 1.2
V
CCIO
= 3.0, 2.5, 1.8,
1.5, 1.2
V
CCIO
= 1.5, 1.35,
1.25, 1.2
±15
I5, C5
±15
C6
±15
%
Unit
50-Ω R
S
±15
±15
±15
%
34-Ω and 40-Ω R
S
±15
±15
±15
%
48-Ω, 60-Ω, and
80-Ω R
S
V
CCIO
= 1.2
±15
±15
±15
%
50-Ω R
T
V
CCIO
= 2.5, 1.8, 1.5,
1.2
–10 to +40 –10 to +40 –10 to +40
%
20-Ω, 30-Ω,
40-Ω,60-Ω, and
120-Ω R
T
V
CCIO
= 1.5, 1.35, 1.25 –10 to +40 –10 to +40 –10 to +40
%
60-Ω and 120-Ω R
T
V
CCIO
= 1.2
–10 to +40 –10 to +40 –10 to +40
%
25-Ω R
S_left_shift
V
CCIO
= 3.0, 2.5, 1.8,
1.5, 1.2
±15
±15
±15
%
1
Calibration accuracy for the calibrated on-chip series termination (R
S
OCT) and
on-chip parallel termination (R
T
OCT) are applicable at the moment of calibration.
When process, voltage, and temperature (PVT) conditions change after calibration,
the tolerance may change.
December 2013
Altera Corporation
Arria V GX, GT, SX, and ST Device Datasheet