Electrical Characteristics
Page 3
Maximum Allowed Overshoot and Undershoot Voltage
During transitions, input signals may overshoot to the voltage listed in
and
undershoot to –2.0 V for input currents less than 100 mA and periods shorter than
20 ns.
The maximum allowed overshoot duration is specified as a percentage of high time
over the lifetime of the device. A DC signal is equivalent to 100% duty cycle.
For example, a signal that overshoots to 4.00 V can only be at 4.00 V for ~15% over the
lifetime of the device; for a device lifetime of 10 years, this amounts to 1.5 years.
lists the maximum allowed input overshoot voltage and the duration of the
overshoot voltage as a percentage of device lifetime.
Table 2. Maximum Allowed Overshoot During Transitions for Arria V Devices
Symbol
Description
Condition (V)
3.8
3.85
3.9
3.95
4
4.05
4.1
4.15
Vi (AC)
AC input
voltage
4.2
4.25
4.3
4.35
4.4
4.45
4.5
4.55
4.6
Overshoot Duration as % of High Time
100
68
45
28
15
13
11
9
8
7
5.4
3.2
1.9
1.1
0.6
0.4
0.2
Unit
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
%
December 2013
Altera Corporation